Adjusting the Support Arms
▲ WARNING! The Support Arms are factory calibrated and do not need any
adjustment out of the box. Do not make adjustments to these screws unless
absolutely necessary, or instructed to do so by Shaper Support.
To restore coplanarity between the Support Bar and the Tape Surface on the Body:
∙ Use a 2mm Hex Wrench (not included) to adjust.
∙ Place a known flat surface (such as a good straight edge) between
the Tape Surface and the top of the Support Bar.
∙ Gently tighten or loosen set screws on each side as needed to eliminate any
gap between your known surface and both top surfaces of the Workstation.
For further assistance, contact Shaper Support
Consumable Items
Replacing the Shelf Top
∙ The Shelf Top is consumable and will eventually need to be replaced.
∙ To replace the Shelf Top, remove the four screws holding the Shelf
Top to the Shelf Body with the included 4mm Wrench.
∙ We designed the Workstation to easily accept shop-made Shelf Tops.
See hole pattern information on page 26.
if you wish to extend the life of your Shelf Top, you can use double sided
tape to apply a thin spoilboard in between your work and the Shelf Top.
Replacing the Spoilboards
∙ Spoilboards are consumable items that will need to be regularly replaced.
∙ remember that each Spoilboard can be reused at least eight times by flipping or
rotating the spoilboard, and using both the left and right sides of the Clamping Face.
∙ We designed the Workstation to easily accept shop-made Spoilboards.
See dimensions on page 26.
MAinTEnAnCE & TECHniCAl DATA
25