1.2 Installation

Fuels
Low smoke, trouble-free operation of the stove and a supply of heat at the nominal
level with a chimney draught of 12 Pa are only guaranteed when you use the follow-
ing fuels and no others.
Only use natural, dry chopped firewood with a remaining humidity of max. 20%, and
lignite (brown coal) briquettes.
With the primary air damper, do you adjust the rated output.
There may be engaged in only the settings and fuel quantities are
given that correspond to your licensed or purchased device.
Adjustment:
Fuel
Warning up,
kindling
Wood
Brown-coal
Putting out of working
order
Filling quantities 8 kW
-Split billet: max. length: 33 cm, max. 2 billets per filling, appr. 1,9 kg
-Lignite briquette: max. 2,1 kg
IT IS NOT ALLOWED to burn waste, fine chipping, bark, wood handled with preven-
tive chemicals, furthermore paper and cardboard. For kindling please use wood
scrapings or grill starter but never use liquid auxiliaries!
The first kindling
At the first fire set-up could be a little smoke, but is not dangerous, normal!
In this time, please ventilate the room carefully!
Warning! Upon the first kindling, smoke and unpleasant smell may be gener-
ated. Always ensure the proper ventilation of the room (by opening windows
and doors), and heat the fireplace at maximum rated heating performance. If
with the first heating the maximum temperature is not reached, the above-
mentioned effects may as well arise later on.
Types of fuels
Hard wood
Soft wood
Brown-coal
Nominal heating
performance
Nominal heating
performance
Heating value appr. kWh/kg
4,0 – 4,2
4,3 – 4,5
5,3 – 5,5
Setting of the pri-
mary air regulator
"A"
8kW
middle right
middle left
Table 2
27
Burning time
-
left
ca. 0,75 h
ca. 1 h
-
right

Publicité

Table des Matières
loading

Table des Matières