Instructions for installation and use
10. Troubleshooting for users
Refer to Fig. 4 (page 15).
10.1. Exceeding heating period
Problem: After switching on, the control light 1 flashes three times and goes
out. The sauna heater does not heat up.
Cause: After running for 6 hours, the sauna control unit automatically switches
off the sauna heater for safety reasons (heating period limit).
How to solve the problem: Follow the following steps to start up the sauna
control unit again:
1. Switch off the sauna control unit using the ON//OFF switch 4.
2. Wait 10 seconds.
3. Use the temperature selector 2 to set the lowest temperature.
4. Switch on the sauna control unit using the ON//OFF switch 4.
5. Use the temperature selector 2 to set the highest temperature.
6. Set the temperature selector 2 back to the lowest temperature.
► The sauna control unit is operational again.
10.2. Light does not operate
How to solve the problem:
1. Switch off the sauna control unit using the ON//OFF switch 4.
2. Switch off the sauna control unit's main fuse on the distribution board.
3. Change the bulbs used for lighting the sauna.
4. Switch the main fuse back on.
5. Press switch 3.
► If the light still does not operate, inform your supplier.
WORLD OF WELLNESS
p. 16/18