Intended Use; Items Supplied; Before Starting The Equipment; Parts Required - EINHELL HGG 300 Niro Mode D'emploi D'origine

Générateur d'air chaud
Masquer les pouces Voir aussi pour HGG 300 Niro:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
Projekt1__ 26.06.13 14:14 Seite 6
GB
3. Layout (Fig. 1)
1 Carry handle
2 Air inlet grille
3 Gas connection thread
4 Gas valve button
5 ON/OFF switch
6 Base
7 Housing
8 Piezo ignition knob
9 Air outlet opening

4. Items supplied

Open the packaging and take out the
equipment with care.
Remove the packaging material and any
packaging and / or transportation braces (if
available).
Check to see if all items are present.
Inspect the equipment and accessories for
transport damage.
If possible, keep the packaging until the end
of the guarantee period.
IMPORTANT
The equipment and packaging material are
not toys! Do not let children play with
plastic bags, foils or small parts!
There is a danger of swallowing or
suffocating!
Gas fan heater
Carry handle with 2 screws
Gas hose
Pressure regulator 1500 mbar
Original operating instructions
6

5. Intended use

The gas fan heater is designed solely for
heating, structural drying and thawing purposes
in well ventilated rooms and outdoors.
Well ventilated rooms have ventilation openings
with a total area of at least 750 cm². A minimum
room size of 300 m³ is compulsory.
The gas fan heater must never be used in
basements or in rooms below ground level. This
gas fan heater is not designed for household
use.
The gas fan heater may be used only for its
intended purpose. Any other use is deemed to
be a case of misuse. The user/operator and not
the manufacturer will be liable for any damage
or injuries of any kind which result from such
misuse.
Please note that our equipment has not been
designed for use in commercial, trade or
industrial applications. Our warranty will be
voided if the equipment is used in commercial,
trade or industrial businesses or for equivalent
purposes.

6. Before starting the equipment

6.1. Fitting the carry handle (Fig. 1)
Use a cross-tip screwdriver and the provided
screws to screw the carry handle (1) to the
housing (7).
6.2 Connecting to the gas cylinder (Fig. 2)

6.2.1 Parts required

The following parts are required to connect
the gas fan heater to the gas cylinder:
A conventional 5 kg or 11 kg (max. 13 kg)
gas cylinder.
A pressure regulator compliant with EN
13785 for 1500 mbar operating pressure,
max. 1.5 kg/h, for the gas cylinder used
(supplied).
A sufficiently long hose line compliant with
EN 1763-1 (max. 1.0 m) which can be fitted

Publicité

Table des Matières
loading

Table des Matières