Instructions for assembly
• Exhaust pipes should be very short with wide curves (no 90°
curves) and no reduction of the diameter.
• Always use pipes with a diameter of not less than 150 mm.
Elbows/bends may not be installed closer than 50 cm in front
of the fan module. Always insert a straight piece of approx. 50
cm between two bends/elbows.
• The cross-section of wall vents and the cut-out in the base
panel should at least correspond to the exhaust air duct.
• During installation, make sure that the convection air unit
remains accessible when the kitchen has been completely
mounted. This means that the levelling feet of the kitchen units
will need to be repositioned if necessary.
40

Electrical connection

• The electrical connection must be carried out by a
qualified electrician who is authorised to carry out such
work!
• Statutory regulations and the connection specifications issued
by the local power supply company must be strictly observed.
• When connecting the appliance it must be ensured that there
is a device which makes it possible to disconnect it from the
mains at all poles with a contact opening width of at least
3mm. Line-protecting switches, fuses o r contactors are
suitable cut-out devices.
When connecting and repairing the appliance disconnect it
from the electricity supply with one of these devices.
• The earth wire must be sufficiently long so that if the strain
relief fails, the live wires of the connecting cable are subjected
to tension before the earth wire.
• Any superfluous cable must be removed from the installation
area beneath the appliance.
• Make sure that the local mains voltage is the same as the
voltage on the rating label.
• Full protection against accidental contact must be ensured on
installation.
• Attention: Incorrect connection may result in the power
electronics unit being destroyed.
Power supply
Mains voltage: 380-415V 3N~, 50/60Hz
Component rated voltage: 220-240V
GB