Ul-Data; Standard Type; Ordering Example For Variants; Connection Example - DOLD BH 5932 Fiche Technique

Contrôleur de vitesse nulle ou lente
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

UL-Data

The safety functions were not evaluated by UL. Listing is accom-
plished according to requirements of Standard UL 508, "general use
applications"
Switching capacity:
Ambient temperature 60°C:
Wire connection:
Technical data that is not stated in the UL-Data, can be found
in the technical data section.
nfo

Standard Type

BH 5932.22/112/61
AC/DC 24 V
Article number:
BH 5932.22/112/61
AC/DC 24 V
Article number:
• Output:
• Nominal voltage U
:
N
• Input:
• Width:
Pilot duty B300
4A 250Vac G.P.
4A 24Vdc
60°C / 75°C copper conductors only
AWG 20 - 12 Sol Torque 0.8 Nm
AWG 20 - 14 Str Torque 0.8 Nm
20 ... 26000 Ipm
0059482
8 ... 14000 Ipm
0065009
2 NO, 1 NC contacts
DC 24 V
for pnp-sensors and with sensor
detection
45 mm

Ordering example for variants

BH 5932 .22 /_ _ _ /61 AC 230 V 50/60 Hz 60 Ipm

Connection Example

L1(+)
A1
X1
X2
13
+IN A
IN A
BH5932
-IN A
A2
14
N(-)
Standard connection
suited up to SIL3, Performance Level e, Cat. 3
21
Setting value
Nominal frequency
Nominal voltage
UL approval
Variants, if required
0 = fixed response
value
1 = adjustable
setting value
channel 1 and 2
ogether ad -
justable
2 = adjustable
setting value
channel 1 and 2
separated ad -
justable
3 = adjustable
setting value
channel 1 and 2
together adjust-
able with fine
tuning to syn-
chro nise both
channels
0 = npn-input
1 = pnp-input
0 = without sensor
detection
1 = with sensor
detection
Contacts
Type
23
31
+IN B
IN B
-IN B
24
32
M7604_b
BH 5932 / 10.12.18 en / 044A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bh 5932.22/112/61Safemaster s

Table des Matières