If the first number entered is a Zero the RouteControl
switches to track route operation: the first posi-
tion in the display will show ".F."! A non-valid entry
of "00" in the track route is automatically changed
into "01". A missing numerical entry following "F. ."
will be corrected to "F.01" or a single digit numeri-
cal input "5" to "05" following the "F" within two
seconds. An erroneous input of a track route number
can also be corrected with the number keys (first
input "0"!) or with the cursor keys. The track route
GB
is activated with the green direction key. The display
will show the separate positions and their turnout
numbers. The LEDs will illuminate momentarily to
show the corresponding settings. After overlay "P
xy" and "F. .". The call-up of a track route can be
stopped by again pressing and keeping depressed
the direction green key or can be canceled by pro-
longed pressing of the red direction key (A cancel-
lation occurs after display of the following position
number). A call-up of an "empty" track route is
shown by three horizontal lines in the display. The
call-up of another track route can be done only after
all setting commands of the preceding track route
have been executed.
Emergency Stop
The Emergency Stop can neither be activated nor
disabled from the RouteControl. If, however, the lay-
out is in an "Emergency-Stop" status it is indicated
by flashing of the appropriate display of the key-
board. Short-circuit and overload conditions are also
Sequence of key use
1.
Unplug RouteControl
2.
Press and keep depressed the "ok" direction key
3.
Reconnect RouteControl for menu adjustments
4.
Release "ok" direction key
5.
With s cursor key change parameter indication to C3
7.
With t cursor key change value to 000
8.
Confirm with direction key "ok"
9.
a) Either use cursor key to select next parameter to be read or changed (ref.
to step 5) or
b) with direction key "esc" return to layout operation (Restart of the Route-
Control)
10
shown during "Maus-Bus" operation in this manner;
alternating vertical bars similar to those of Lokmaus
2
indicate these conditions during DataBUS opera-
®
tion. Operation of turnouts or call-up of track routes
is not possible during emergency stop condition. If
emergency stop or short-circuit status is triggered all
further activation of setting commands is halted but
will be continued automatically after the emergency
stop has been resolved.
If programming is done with Lokmaus 2
100) the display will show the indication "PA" indi-
cating that at this time no setting- or search activity
is possible.
Settings
(Changes are stored permanently)
To enter the RouteControl setting menu ist
plug must be pulled, the "Straight/ok" key must
be pressed and kept pressed while the plug is
reinserted: the display shows "CO". The "Straight/
ok" key serves to call up setting values as well as
confirmation of changes after reprogramming, while
moving through the menu. The "Divergence/esc" key
is used to discontinue the search and return to layout
operation from the menu. Value changes in the menu
settings can only be carried out with the cursor keys
but not with the numerical keys!
Example: All track routes have just been pro-
grammed and the protection against accidental
change should be activated (see the following table
"Menu System"):
(or Lenz LH
®
Display indication
dark
dark
C0
C0
C3
000
C3
C..