TECHNICAL DATA

C1

Main specifications

ODOURLESS HOOD
Power supply
Power supply voltage
Frequency
Max. absorbed power
Max. absorbed current
Power cable
Extraction motor power
Catalytic converter element
power
Water supply
Supply water pressure
Water supply temperature
Condenser capacity
Air treatment
Emitted air temperature
Noise emission
Decibels
Sound pressure
Other data
Weight
Water filling time
Table
2
Main
characteristics,
and consumption.
V
220/240
Hz
50
kW
2.5
A
9
-
3x2
kW
0.4
kW
2.25
kPa [bar]
1.5÷2.5
° C
5÷25
° F
41÷77
L
2
° C / ° F
120 / 248
<
70dB(A)
<
63 Pa
kg /lbs
66 / 125.5
sec.
30
performance
29
C2

Power supply characteristics

The machine's AC power supply must meet the following
conditions:
• Max. voltage variation ±6%;
• Max. frequency variation ±1%;
ATTENTION!
The machine's power supply must be
protected against overcurrents (short
circuits and overloads) by fuses or
suitable thermal-magnetic switches.
ATTENTION!
The protection rating against water
entering is: IPX4.
For protection against indirect contacts
(depending on the type of supply
foreseen and the connection of the
masses to the equipotential protection
circuit) refer to par. 6.3.3 of EN 60204-1
(IEC 60204-1) with the use of protection
devices
that
disconnection of the power supply in
case of an insulation fault in TN or TT
systems or, for IT systems, the use
of isolation controllers or differential
current protection devices to start
automatic disconnection of the power
supply (except when a safety device
is provided to disconnect the power in
case of a first fault to earth, an isolation
controller must be provided to indicate
the occurrence of a first fault by a live
part to the masses or to earth. This
device must activate an audible and/or
visual signal which must continue for
the duration of the fault).
For example, in a TT system it is
necessary to install a differential circuit
breaker upstream of the supply with
intervention current coordinated (e.g.
30mA) with the earthing system of the
building where the machine is to be