WHEN USING A SOLID PACK CHIMNEY

Cement board and steel studs
Face must have a
minimum 8' height
Cement board from
the side of the unit
5.2

WHEN USING AN AIR COOLED CHIMNEY

W415-0594 / E / 10.19.12
on enclosure ceiling
not required above 10'
Cement board
of cement board
depending upon
ceiling height
combustible
facing and wood
framing may start
at 96" above the
base of the unit
to combustibles
Metal Studs
Cement board
Face must have a
minimum 7' height
of cement board
combustible
facing and wood
framing may start
at 84" above the
base of the unit
Cement board from
the side of the unit
to combustibles
ENCLOSURE CEILING
FLOOR JOISTS
METAL STUDS
CEMENT BOARD
MINIMUM 7' TO BASE OF THE FIREPLACE
The appliance face and
enclosure ceiling must
be framed using 2x4
metal studs.
The minimum
enclosure ceiling height
is 7 feet.
Non - combustible
materials (cement
board and metal studs)
must be used.
Metal Studs