FloTech Programmable CheckMate Retain / Overfill Monitor
Fig. 10
Timer/Reset and AUX Connections
TB2 PROGRAM Connections
Refer to Fig. 11. The FT208 Monitor must have a program module
installed in the PGM terminals ONLY during programming of the
monitor. This connection must be left open for normal operation.
See the Programming Section of this manual for detailed
instructions about programming this unit.
Programming
Overview
Before the FloTech FT208 Monitor can be put into service, it must
be programmed. This procedure informs the monitor which inputs
have sensors attached. These inputs are then labeled as ACTIVE
sensors. The remaining inputs that do NOT have sensors attached
are labeled as INACTIVE inputs. This insures that a PERMIT
signal will be issued only if ALL of the following conditions are
met:
Page 14
REV G
FT208 CheckMate