Tb1 Power Connections; Tb2 Top And Bottom Sensor Connections - FloTech FT208 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FloTech Programmable CheckMate Retain / Overfill Monitor
wire the monitor to a positive ground system will damage the
monitor and void the warranty.

TB1 POWER Connections

Refer to Fig. 4. FloTech recommends routing the trailer power
through a weatherproof inline fuse holder (supplied) containing a
1/2 amp fast blow fuse to the monitor. Optionally, a switch can be
added in series with the fuse to the TB1 input. Connect the
positive power supply wire to the TB1 terminal marked "12/24
VDC". This is the upper screw on TB1. Be careful that no stray
wires are touching the metal barrier or ground terminal. The
Ground wire connects to the TB1 terminal marked GND.
Fig. 4
Monitor Power Connections
TB3 & 4 TOP and BOTTOM SENSOR Connections
FloTech FT208 can be wired to work with 2 wire FT151 sensors or
API 5 wire FT101 sensors. FloTech recommends wiring the
sensors to the FT208 Monitor using FT404 11 conductor cable for
up to 8 compartment systems. FloTech FT404 cable is color coded
to ease installation and troubleshooting. A color coded wiring
schematic is provided in the back of this manual.
Page 10
REV G
FT208 CheckMate