KSK-...
S
Remove the coulping screws of the di-
vided half-shells.
S
Clean the contact surfaces of the coupling
and the drive pin.
These will only function correctly if they
are free of oil and grease.
S
Push the couplings in each case with the
non-divided hub as far as possible onto
the drive pin of the DGE-...-ZR.
Turn the coupling screws slightly in order
to fasten the coupling.
S
Place the connecting tube in the open
couplings.
S
Compare the support depth B of the con-
necting tube with the minimum value.
Type KSK-
Min. support
depth B
If the support depth is too small, you
must correct this by shifting the coupling
away from the stop and towards the tube.
S
Tighten the coupling screws of the non-
divided hubs (Ms).
Type KSK-
Ms
20
25-...
40-...
63-...
10.2
13.1
21.6
25-...
40-...
63-...
4 Nm
8 Nm
50 Nm
Fig. 11
Fig. 12
Fig. 13
Fig. 14
B*
Fig. 15
Festo KSK-... 0010NH English