Detecting Faults
FAULT: The machine doesn't work
Possible cause
Machine not plugged in.
No power is reaching the plug.
Cover not itted properly.
Juice container not itted properly.
Blocked pressing units.
Safety sensors malfunctioning.
Faulty ON/OFF button.
Faulty circuit.
FAULT: The machine blocks frequently during juicing
Possible cause
Insuficient voltage.
Faulty circuit.
FAULT: The pressing units are not synchronized
Possible cause
Fault in an axle.
FAULT: Peel ejector breaks
Possible cause
Peel ejector incorrectly itted.
FAULT: You can hear the motor running but the pressing units are not turning
Possible cause
Internal fault.
Detecting Faults
52
English
Correction
Plug it in.
Check the socket.
Make sure it has been it properly.
Make sure it has been it properly.
Turn off the machine at the mains and
unblock the pressing units.
Contact your technical service.
Contact your technical service.
Contact your technical service.
Correction
Check that the voltage matches that indicated in the manual.
Contact your technical service.
Correction
Contact your technical service.
Correction
Place it in its correct position inserting it totally
until observing it has madecontact (Fig. 8)
Correction
Contact your technical service.