Scope of supply
Position
Description
0
Power supply module ECSEExxx
2
Accessory kit with attachment material
Mounting instructions
Drilling jig
)
Note!
The connector set ECSZE000X0Bmust be ordered separately.
Connections and interfaces
Position
Description
X22
Connections
External brake resistor
l
DC−bus voltage
l
l
PE
1
LEDs: Status and fault display
X1
Automation interface (AIF) for
Communication module
l
Operating module (XT keypad)
l
X2
PE connection AIF
X3
Not assigned
X4
CAN connection
System bus (CAN)
l
Interface for
l
– master control and other modules
– PC/HMI for parameterisation and diagnostics
X6
Connections
l
Low−voltage supply
Digital inputs and outputs
l
Thermostat contacts
l
S1
DIP switch
CAN node address (device address in the CAN network)
l
CAN baud rate
l
X21
Mains connection
Status displays
LED
Red
Green
Off
On
Off
Blinking
Blinking, 1 Hz
Off
Blinking, 3 Hz
Off
Blinking, 1 Hz
Blinking
Blinking, 1 Hz
On
46
Description
Power supply module is enabled, no fault
Power supply module is inhibited (CINH), switch−on inhibit
Fault / error (TRIP) / short−circuit braking error (KSB−TRIP) is active
Message active
Warning active with inhibited module
Warning active with enabled module
l
Number
1
1
1
1
Detailed
information
^
71
^
83
^
82
^
68
EDKCSEE040 DE/EN/FR 3.0