Operation
11.
Selector switch
Mode selection
Set the pulse speed and energy output using the Selector switch:
Mode
Off
Full energy
Half energy
Night
Day
Battery
indicator
For all modes, if the battery reaches critical voltage, then the
energizer will not pulse and will show the Battery indicator.
Day / Night
day time
night time
day time
night time
Full battery
Off
Full energy,
1.5 s pulse interval
Half energy,
1.5 s pulse interval
Off
Full energy,
1.5 s pulse interval
Full energy,
1.5 s pulse interval
Half energy,
3 s pulse interval
Half energy,
3 s pulse interval
Low battery
Off
Half energy,
3 s pulse interval
Half energy,
3 s pulse interval
Off
Half energy,
3 s pulse interval
Half energy,
3 s pulse interval
Half energy,
3 s pulse interval
Half energy,
3 s pulse interval
51