Wiring; Operation With Ecsxe Power Supply Module - Lenze ECSDK Serie Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.4

Wiring

Install the capacitor module between the power supply module and the axis mo-
dule(s).
If the total cable length in the DC−bus connection is longer than 5 m, install the ca-
pacitor module as close as possible to the axis module with the highest power.
4.4.1

Operation with ECSxE power supply module

(
Stop!
ƒ
ƒ
Fig.9−1
Level/time diagrams for operation with ECSxE power supply module
ECSxü
ECSxE
U
ECSxK
K1
EDKCSDK002 DE/EN/FR 1.1
Operation with ECSxE power supply module
Permanently bridge the charging current limitation (X26) of the
capacitor module (X26 = HIGH).
Only release the controller (X6/SI1 = HIGH) if the power supply
module ECSxE displays "Ready for operation" (X6/DO1 = HIGH).
HIGH (1)
ü
ECSx : X6/SI1
ECSxE: X6/DO1
LOW (0)
U
ZK
HIGH (1)
ECSxK: X26 (24 V DC)
ECSxE: X6/DI1
ECSxE: X6/DI2
LOW (0)
HIGH (1)
K1
LOW (0)
Axis module of series ECS
Power supply module of series ECS
DC−bus voltage
ZK
Capacitor module of series ECS
Mains contactor
Electrical installation
100 %
0 %
l
4
Wiring
t [s]
t [s]
t [s]
t [s]
ECSXK010
59

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ecsdk001Ecsdk002

Table des Matières