Led / Remote Receiver / Thermostat Replacement; Fuse Replacement - Napoleon NEFB30GL Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.3

LEd / REmOTE RECEIvER / ThERmOSTAT REPLACEmENT

TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED
SERVICE PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
1. To replace LED lights in the ember bed, flame and/or decorative lights, disconnect the quick connect plug
from the control board and replace with a new one.
2. To replace the remote receiver and thermostat wires, disconnect the quick connect plug from the control
board and replace with a new one.
6.4

FuSE REPLACEmENT

1. Remove the plastic cover from the fuse. pull the fuse (2Amp) out from the control board. Install the re-
placement fuse and plastic cover.
WARNING
!
19
EN
W415-2166 / A / 06.29.16