3.3
NEw CONSTRuCTION OR RENOvATION
A.
Select a location that is not prone to moisture and is located at least 0.9 m or 3 feet away from
combustible materials such as curtains or drapes, furniture, bedding, paper, etc.
place the appliance in selected location to see how it will look in the future.
B.
Mark the desired location on the floor and store appliance in a safe, dry and dust free location.
C.
Frame in an opening leaving at least 1/4" (6 mm) around the edge of the appliance. Any new wiring
D.
must be done in compliance with local and national codes and other applicable regulations in order
to reduce the risk of fire, electric shock or other injuries. Therefore, it is strongly recommended that
you hire a professional to complete any such work.
3.4
INSTALLING ThE APPLIANCE
Once the site has been prepared, the appliance can be installed.
A.
Make sure the main power switch is in the "OFF" position.
B.
plug the appliance into a 15-amp/120 volt, grounded outlet. Use a CSA or UL approved surge
C.
protector.
push in the appliance so that the trim is against the finished mantel or wall surface.
D.
3.5
ThERmOSTAT ANd ThERmAL SENSOR INSTALLATION
This appliance has two options for heat control.
First is a thermal controlled sensor, which comes plugged into the appliance beside the main power cord.
This sensor has no user temperature set points, it will turn off the heater when the sensor reaches its pre-set
point, and will only turn the heater back on when it has cooled back down below this set point. On the low
setting (green light) the set point is 16°C/61°F, on medium (orange light) 22°C/72°F and on high (red light)
28°C/82°F. This small sensor can be placed anywhere in the room within the length of the sensor wire, but it
should not be placed near the top or front of the appliance. placing the sensor too close to the heater area of
the appliance will cause unwanted cycling of the heater.
Second is the option of a wall-mounted thermostat. Napoleon part # w690-0001, w660-0081, or an equiva-
lent low voltage thermostat.
A wall thermostat can be used in place of the thermal control sensor. You must first remove the sensor by un-
plugging it from the right side of the appliance beside the main power cord. Replace the sensor with the wire
harness provided in the manual baggie. plug it into the appliance and connect the other end to the thermo-
stat. The thermostat should be placed as per the thermostat installation instructions.
w680-0022
Thermo-controlled sensor
5m Temperature Probe (included)
11
EN
W415-2166 / A / 06.29.16