rEfUELLINg
Refuel with new wood only when the loading chamber has a bed of embers left.
If there is too much unburned fuel in the combustion chamber, it can flare up when the upper door is opened.
prEss the MENU button twice to increase the smoke fan's suction power to 100% in order to prevent smoke from coming
out from the loading chamber when the door is opened to refuel new wood.
WATER Temp.
100 % SMOKE MOTOR OPERATION ON
MANUAL operation
Open the upper door of the loading chamber slightly by lifting the handle and waiting a few seconds in this position in order to enable the
fan to suck up any smoke.
Now open the door in order to refuel with new wood, lowering the handle slightly to release the
door's safety lock.
If there is a bed of embers, pile the new wood limiting the space between one log and another.
After refuelling, close the upper loading door.
The ignition door, which is located under the upper loading chamber door, must remain slightly
open until the smoke temperature reaches 180 - 210 °C.
Upon reaching the said temperature, the door must be closed.
IMporTANT: When refuelling, you must keep in mind the smoke temperature.
If the smoke temperature drops below100 °C for more than 10 minutes, the boiler will go off.
In this case, you must restart the boiler as described above in the section regarding "IGNITION".
opErATIoN
IF THE ACTUAL TEMPERATURE OF DISCHARGE SMOKE EXCEEDS THE NOMINAL VALUE OF 290°C, THE FAN
DECREASES ITS POWER AND MODULATES IT WITH REDUCED POWER.
ONCE ALL THE WOOD HAS BURNED, THE FAN STOPS AFTER THE SMOKE TEMPERATURE HAS DROPPED
BELOW 100 °C FOR MORE THAN 10 MINUTES (DEFAULT SETTING).
THE BOILER'S CIRCULATOR OPERATES BASED ON THE DIFFERENTIAL TEMPERATURE BETWEEN THE BOILER
AND THE PUFFER. IF THE BOILER'S TEMPERATURE DROPS BELOW THE TEMPERATURE OF THE PUFFER, THE
CIRCULATOR STOPS.
IF THE PUFFER PROBE IS DISABLED, THE CIRCULATOR GOES OFF DURING THE COOLING PHASE OF THE
BOILER 3°C BELOW THE TEMPERATURE SET IN "SET PUMP IGNITION TEMPERATURE".
56
SMOKE
AIR
ENgLIsH
PRESS the MENU button
Confirm MENU items
100 % SMOKE MOTOR OPER