CHIMNEY poT
Flue draught also depends on the suitability of the chimney pot.
chimney pots must meet the following requirements:
1.
have a useful output section of more than double the length of the fireplace/pipe system into which it is inserted
2.
be compliant in order to prevent rain and snow from penetrating into the fireplace/pipe system
3.
be constructed in such a way that even in the case of winds from all directions and with any inclination, evacuation of combustion
products (windshield terminal) is ensured.
boILEr CoNNECTIoN To THE MAINs poWEr sUppLY
The boiler is supplied with a power supply cable (plug NOT supplied) to be connected to a 230V 50 Hz outlet, possibly with a circuit breaker.
The power supply outlet must be easily accessed. The electrical system must be compliant; in particular, check efficiency of the earthing
circuit. Improper system earthing can cause malfunctions, which the manufacturer is not liable for. Power variations greater than 10% can
cause product malfunctions.
The product must be installed and connected by qualified personnel in compliance with current regulations. (See Chap. SPECIAL
WARNINGS).
NorDICA s.p.A. shall not be held liable for unauthorised product modifications as well as use of non-original spare parts.
WARNING: the boiler must be connected to the mains with an upstream differential line cut-off switch according to the
regulations in force. Connect the power supply cable of the boiler to a bipolar switch with minimum distance between
contacts of 3mm (Power supply 230 V~ 50 Hz; correct system earthing is essential).
The power supply cable must be checked regularly and kept in its original status. Any type of intervention on the safety circuits and
single elements is forbidden so as not to compromise safe and reliable operation of the boiler. In the event of damage to the electrical
system, decommission the boiler, disconnect it from the power supply and ensure professional repair is carried out in compliance with
legal regulations.
ATTENTIoN, the power supply cable must NoT come into contact with hot parts.
Installation, relative system connections, commissioning and verification of correct operation must be carried out correctly by professionally
qualified and trained personnel in full compliance with current national, regional, provincial and municipality regulations in the country
where the appliance is installed.
ELECTrICAL CoNNECTIoNs
NON FORNITO
NOT SUPPLIED
NICHT IM LIEFERUMFANG
PAS FOURNIS
NO SUMINISTRADO
48
boiler power supply 230 v / 50 Hz
fuse 3,15 A
smoke suction fan motor
Circulator output
smoke probe
puffer probe
output potential free contact