opEN vEssEL INsTALLATIoN.

The diagrams are purely indicative, therefore they do not have design value.
Installation, relative system connections, commissioning and verification of correct operation must be carried out correctly by professionally
qualified and trained personnel in full compliance with current national, regional, provincial and municipality regulations in the country
where the appliance is installed.
Size the system correctly to avoid long pause times that would cause significant problems like the ones mentioned in the section regarding
DOWN-FIRED BOILER OPERATION.
ATTENTIoN : the boiler's circulator operates based on the differential temperature between the boiler and the puffer. if the
boiler's temperature drops below the temperature of the puffer, the circulator stops.
3
2
VSP
VST
1
1
LNK down-fired boiler
2
Thermal Discharge Valve
3
Safety valve 1.5 bar
4
Thermometer
5
Pressure gauge
6
Open expansion tank OET
7
Circulator
8
Heating device controller
9
Circulator
10
Puffer
11
Plate Exchanger
12
Domestic hot water production
13
Auxiliary boiler (gas, methane, LPG or Diesel)
14
Radiator system (high temperature)
15
Radiant panel system (low temperature)
16
Expansion tank
17
Complete system separator KIT that can be supplied as an ACCESSORY
18 (*)
NTC probe - cable length 5 m
(*) IMporTANT: The buffer tank probe position is illustrative. The real position has to be evaluated with the installer/designer.
50
VEAC
V
S
6
4
5
8
T
M
65°C
11
7
SP
17
CA
TS
VMS
12
18
9
75°C
10
Can be coupled to boiler model LNK 15, LNK 20 and LNK 30.
With regard to model LNK 40, consider a KIT with a suitably
sized plate heat exchanger (PHE).
NOT included in the system separator KIT.
Can be supplied as an OPTIONAL accessory
ENgLIsH
13
14
R
16
VE
15
VM