INsTALLATIoN
rECoMMENDED DIsTANCEs of THE boILEr rooM
In compliance with current regulations, boilers must be installed in rooms having sufficient ventilation required for combustion. It is not
permitted to install boilers in living spaces (including corridors). The minimum overall dimensions of the opening for combustion air in the
boiler room must be minimum 100 cm per boiler. Besides the boiler, the thermal control unit must also accommodate the inertial storage
tank, hot water boiler, electrical panel and all water plant engineering.
LNK 15
LNK 20
I
500
500
II
500
500
III
600
600
IV
150
150
Space required with the cleaning lever on the left -
standard version supplied.
fIrE proTECTIoN for INsTALLATIoN AND UsE of THErMAL DEvICEs
WArNINg In situations of possible presence of gas, flammable vapours and with works that constitute temporary danger of fire or
explosion (laying of linoleum with glue, PVC, etc.), the boilers must be disconnected before the said danger can be generated.
objects made of flammable material must not be placed on the boiler or closer than the safety distance.
46
LNK 30
LNK 40
500
500
500
500
700
700
150
150
Space required with the cleaning lever on the right -
inversion by a qualified technician.
ENgLIsH