CAUTION
230
120
FI
Approval Marks

TECHNICAL DATA

Voltage
Frequency
Power consumption
Temperature
Airflow (50-100%)
Drive speed
Noise emission level
Dimensions
Weight
10
Danger! Unplug the tool before opening it, as live compo-
nents and connections are exposed.
Incorrect use of hot air tools can present a fire and explosion
hazard, particularly in the proximity of flammable materials
and explosive gases.
Danger of getting burned! Do not touch the end of the
heater tube and nozzle when they are hot. Let the tool
cool down. Do not point the hot air flow in the direction of
people or animals.
Connect tool to a receptacle with protective earth terminal.
Any disconnection of the protective conductor in or outside
the tool is dangerous!
Only use extension lead with protective conductor.
The rated voltage stated on the tool must correspond with
the mains voltage.
For personal protection, we strongly recommend the tool to
be connected to an RCCB (Residual Current Circuit Breaker)
before using it on construction sites.
The tool must be operated under supervision.
Heat can ignite flammable materials which are not in view.
Protect the tool from damp and wet.
Protection Class Ι
230 #
V~
Hz
50 / 60
W
2300
°C
20 – 620
l/min.
max. 300
m/min.
1.0 – 7.5
L
(dB)
67
pA
420 ×270 ×210
mm
kg
11.5
120 #
50 / 60
1800
20 – 620
max. 250
1.0 – 7.5
65
420 ×270 ×210
11.5
#
Mains voltage is not reversible
CCA certified
100 #
50 / 60
1500
20 – 620
max. 250
1.0 – 7.5
65
420 ×270 ×210
11.5

Publicité