Cooke & Lewis CLEC1BK-C Mode D'emploi page 20

Table de cuisson vitrocéramique 60 cm
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical and legal
GB
IE
information
Electrical Requirements
Any permanent electrical installation must comply with the latest
I.E.E. Regulations and local electricity company regulations. For
your own safety a qualified electrician or contractor who is on the
roll of the National Inspection Council for Electrical Installation
Contracting (NICEIC) should undertake the electrical installation.
Electrical Connection
Before connecting the mains supply ensure that the mains
voltage corresponds to the voltage on the rating plate inside
the appliance.
WARNING: THIS APPLIANCE MUST BE EARTHED
The appliance is supplied with a 5-core mains cable and must be
connected to the electricity supply via a double pole switch having
a 3mm minimum contact gap on each connector.
For UK only
A Switched Fused Connection Unit to BS 1363 Part 4 is
recommended.
The fuse must be rated at 30 Amps.
The wires in the mains lead are coloured in accordance with the
following code:
Black + Brown = L - Live
Grey + Blue = N - Neutral
Green/Yellow =
The connection point must be placed in a position adjacent to the
appliance so as to be readily accessible for an engineer in the
event of a breakdown.
Disconnect the appliance from the mains supply before
carrying out any kind of maintenance or cleaning.
20
- Earth

Hide quick links:

Publicité

Chapitres

Table des Matières
loading

Table des Matières