A
Adjust door handing if needed.
RX (request to exit) utilizes a microswitch inside the lock case to detect
rotation of the inside knob/lever.
The RX is a removable module located on the bottom edge of the lock
chassis. The module must be properly positioned to detect inside knob/
lever rotation. If not properly positioned, the lock and/or microswitch may
be damaged.
LH
Left Hand
LRB
Left Hand
Reverse Bevel
If Handing screw is NOT on the INSIDE of door follow A1 and A2 steps.
A1 Remove the RX module and handing screw.
Handing screw and micoroswitch must be on
the INSIDE of the door.
Image
shows RH
RX module
installation.
A2
Reinstall the handing screw onto the inside of door, then
reinstall RX module with the microswitch also on the inside
of the door.
A3
Rotate the latch 180° (if necessary).
Pull
2
INSIDE
Right Hand
OUTSIDE
INSIDE
Right Hand
OUTSIDE
Reverse Bevel
NOTICE
Handing screw
Microswitch
180˚
B
Install strike.
RH
C
RRB
Deadbolt (LEMD) Only: Install door position switch and
magnet.
Feed the wires from the connector on the door position switch into the
long angled hole in the door. Plug the connector into the chassis. Do not
push in switch all the way, leave a little slack until the chassis is installed
after step 1.
Make sure the door position
magnet in the jamb is aligned
with the switch in the door edge!
Insert
magnet into
door jamb
DPS strike box
Magnet (for non-deadbolt models only)
Deadbolt (LEMD) models will not have a
DPS magnet
Strike
(10-136 shown)
NOTICE
Connect
cable to
chassis