3M™ Full Facepiece Respirators 6000DIN Series
Fig. 7
3M™ H-Series Hoods
1. Follow the set-up steps outlined in the H-Series Hoods User Instructions. These instructions describe the set-up of the selected suspension, chin
strap, shroud and faceshield covers. After the hood has been assembled follow the instructions below:
2. Insert the collar end (non-threaded end) of the H-115 or GVP-122 breathing tube into the air inlet at the back of the hood. The breathing tube
should be inserted a minimum of 3 inches.
3. Place the plastic squeeze clamp approximately 1 1/2 inches above the end of the air inlet and squeeze in place to secure the breathing tube to
the hood.
4. Place the hood on your head and let the breathing tube unwind in the back.
5. Screw the breathing tube inlet into the belt-mounted PAPR outlet. Activate the unit with the power switch on the battery pack.
3M™ L-Series Headgear
Fig. 8
Other Approved Headgear
For headgear not listed here, refer to the User Instructions for the specific headgear to be used for information on connecting the breathing tube.
Performance Check with 3M™ Flow Meter
Prior to using this PAPR, complete the test described below to check the status of the battery, filter/cartridge, breathing tube and airflow.
Failure to pass a user performance check and complete all necessary repairs before use may adversely affect respirator performance and
result in sickness or death.
Flow Meter
The flow meter is designed to check airflow being supplied by the GVP PAPR unit. This process should be followed prior to each use. Check the
label on the meter to determine which test circle will be used for the airflow test.
1. Ensure that the filter selected for the workplace is secured to the PAPR before testing airflow.
2. Attach the appropriate breathing tube to the PAPR outlet (see above). Exceptions:
a. If the L-122 Breathing Tube is used, the 3M™ L-181 Adapter must be used instead of the breathing tube to check the airflow. The GVP-113
Flow Meter will not fit into the end of the L-122 Breathing Tube.
b. If a BT series breathing tube is used, the V-199 adapter must be used instead of the breathing tube to check the air flow. The GVP-113 Flow
Meter will not fit into the end of the BT series breathing tube.
3. Turn the power on by pressing the toggle on the GVP-111 battery or turning the switch to the "ON" position for the BP-15 battery.
4. Insert the tapered end of the airflow meter:
a. L-181 adapter – insert into the vinyl connector (Fig. 9) and hold vertically.
b. GVP-122, GVP-123 or H-115 – insert into the end of the breathing tube (Fig. 10) and hold vertically.
c. V-199 – insert into the end of the adapter (Fig. 11) and hold vertically using the thumb and forefinger to cover the two breathing tube locking
slots in the connector (Fig. 12).
5. Locate the position of the ball in the airflow meter.
Fig. 9
1. The 6000DIN Series Full Face Respirator must be equipped with the 6884 DIN Port Adapter.
2. Remove the 7890 plug from the center port of the 6884 adapter.
3. Be sure a 6876 breathing tube gasket is in the port. If not present, install a new 6876 gasket.
4. Ensure a 6895 inhalation port gasket and 6880 bayonet cap are attached and secure on each of the side
bayonet ports.
5. Screw GVP-123 breathing tube elbow adapter into the center port of the 6884 adapter (Fig. 7).
6. Screw the breathing tube inlet into the PAPR outlet.
7. Follow donning and user seal check procedures described in the User Instructions provided with the 6000DIN
facepiece.
8. Activate the unit with power switch on the battery pack.
1. Follow the assembly and set-up procedures outlined in the L-Series Headgear User Instructions. These
instructions describe the methods used to properly configure the headgear for operation. After the headgear
has been properly assembled follow the instructions below:
2. Insert the rectangular end of the 3M™ L-122 Breathing Tube into the air inlet of the L-Series Headgear. Push
until the clamp snaps into place (Fig.8).
3. Place headgear on your head and let the L-122 breathing tube unwind.
4. Screw the threaded end of the L-122 breathing tube into the PAPR outlet.
5. Activate the unit by pushing the power switch on the battery pack.
Fig. 10
WARNING
Fig. 11
8
OK
OK
Fig. 12