Troubleshooting

6
Troubleshooting
Problem / Symptom
If engine doesn't start, check that:
If engine starts but there is no
power at receptacles, check that:
If engine starts but runs erratically,
check that:
If the GFCI trips when a load is
connected, check that:
Reason / Remedy
Engine switch is on "Start".
Fuel valves under fuel tank and on engine are open.
Fuel tank has fuel.
Choke lever is in correct position. Choke should be closed when
starting a cold engine.
All loads are disconnected from generator.
Spark plug is in good condition.
Spark plug cap is tight.
Engine oil level is adequate.
Circuit breaker is closed.
Connector from generator to control panel is tight.
Hose routing from the fuel tank to the engine is correct. For
proper operation, the hose must run through the bushing in the
lifting bracket. Refer to the Parts Book for illustration.
The connected equipment may be wired incorrectly or faulty.
Contact equipment supplier.
See section Determining Power Requirements.