Starting—GP3800A, GP5600A, GP6600A
Before starting, be sure you read and understand all the safety and operating
instructions in this manual.
1. Ensure that the generator is properly installed in an outdoor location. See
Operator Safety while using Internal Combustion Engines for installation
warnings and safety guidelines.
2. Disconnect all loads from the generator and place the main breaker in the "OFF"
position (a2).
3. Set the Auto Idle Switch (c) to "OFF".
4. Open the fuel valve (d1).
Note: If the engine is cold, move the choke lever to the closed position (e2). If the
engine is hot, set the choke to the open position (e1).
5. Turn the engine switch to "ON" (b1).
6. Pull the starter rope (f).
Note: If the oil level in the engine is low, the engine will not start. If this happens,
check the oil level and add oil as needed.
7. As the engine warms up, move the choke lever to the OPEN position (e1).
8. Allow the engine to warm up for a few minutes before placing the main breaker
in the "ON" position (a1) and attaching loads.
4.26
Stopping—GP3800A, GP5600A, GP6600A
1. Turn off and disconnect all tools and appliances attached to the generator.
2. Place the main circuit breaker in the OFF position (a2).
3. Place the engine switch to OFF (b2).
4. Close the fuel valve (d2).
Note: To stop the engine quickly in an emergency, turn the engine switch to OFF
(b2).
a1
a2
e1
e2
b1
c
b2
42
d2
d1
f
wc_gr014176