main working elements of the machine
(A) Automatic diameter and distance measuring arm
(b1) Automatic width measuring arm (if present)
(b2) Automatic width measuring ultrasonic sensor (optional)
(D) LCD monitor
(E) Control keypad
(F) Side flange holder
(G) Weight tray
(H) Wheel support shaft
(I)
Handling holes (TECO 680)
(J)
Wheel guard
(L)
Control pedal PL
I
F
ElECTriCal HooK-UP
On request, the wheel balancer can be set up by the manufacturer to operate with the power
supply available in the place of installation. The set-up data for each machine are given on
the machine data plate and on a special label attached to the power supply connection cable.
CAUTION
Any operations for hooking up to the workshop electrical board must be carried out
only by qualified technicians in compliance with the regulations in force, under the
responsibility and at the charge of the customer.
- The electric hook-up must be performed according to:
• absorbed power specifications indicated on the machine data plate;
• the distance between the machine and the electric hook-up point, so that voltage drops
under full load do not exceed 4% (10% when starting up) of the rated voltage specified
on the data plate.
- The user must:
• fit a plug that respects the current regulations onto the power supply cable;
Operator's manual TECo 680 - 680 PlUS - 680 PlUS Pl
D
E
A
G
I
J
B2
H
10
EN
75