9a
9b
between the calibration template and the support itself (Fig. 9d) is reached, procee-
ding as follows:
1. Fix the ultrasonic sensor calibration template in the kit using the centering accesso-
ries on the shaft of the oscillating unit;
2. Lower the wheel guard;
CAUTION
Lowering the wheel guard enables the launch of the swinging group with the
blocked template !!!
3. Align the ultrasonic sensor calibration template to the ultrasonic sensor support and
check its distance, ie:
a.
270mm (tolerance +/- 5mm)
9c
9d
IMPORTANT: after installing the ultrasonic sensor, calibrate the sensor as described
in the paragraph "Calibrating ultrasonic width measuring sensor".
After installing the machine, move into the selected location, ensuring that the spaces sur-
rounding the machine comply with the minimum dimensions indicated in Fig. 7/7a.
Operator's manual TECo 680 - 680 PlUS - 680 PlUS Pl
74