Start Up - Sagola 4600 Xtreme Manuel D'utilisation

Pistolets aérographes
Masquer les pouces Voir aussi pour 4600 Xtreme:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 67
Fit the new tip and tighten. Now fit, in this order, the new needle, the spring and spring stop and
the product regulator. Lastly, fit the appropriate air nozzle.
There are Tip + needle Kits for this model of Ø 1.20, 1.20XL, 1.30, 1.30XL and 1.40.
10. Air Nozzle Kits
Air Nozzle Kits DVR TITANIA, DVR AQUA, DVR HVLP and DVR CLEAR.
Aircap
Air consumption
DVR TITANIA
320 L/min
DVR AQUA
290 L/min
(*) PRESSURE FOR TEST CHECKER: With the HVLP nozzle You must not exceed the maximum inlet pressure of 1.8
bar. An excess pressure will create an additional over spray and will reduce the transfer.
11. Start-up
Before each start-up and especially after cleaning or repairing the unit, a check must be made that
all its elements are securely tightened.
If maintenance or repair work is to be carried out, the gun must be depressurised before work
begins (without air pressure). Should this safety measure not be observed, this may lead to
malfunctions, personal injury and accidents, which may prove to be fatal. SAGOLA S.A. does not
accept any responsibility for the consequences of any non-compliance with these safety regulations.
Open the spray width (No.10) and product regulators
(No.20) completely (without removing these from their
housing) by turning these anticlockwise. (See Fig.1 and
Fig.2)
Place the pistol on a support so that the axis of the tank is
vertical.
Pour the product to apply into the tank. Until the level is a maximum of 20-25 mm. below the edge
of the tank.
Tighten the filler cap firmly. In the version with the non-drip cap, tip it forward (paint up) or back (paint
down) as necessary.
Connect the gun to the compressed air network. (See
Fig.3)
Adjust the air pressure in the network regulator in order to
compensate for any pressure drop in the network (estima-
ted at 0.6 bar for each 10 m of hose).
Adjust the air pressure in the air nozzle by operating the
flow regulator (see Fig.4), until the required quality of finish
is obtained (better finishes are not obtained with higher
spraying pressures and these lead to lower performance
and worse product transfer).
Position the air nozzle spraying orifices appropriately
(when an imaginary line is drawn through the 2 lugs (see
Fig.5), this must be parallel or perpendicular to the floor).
Fully close the product regulator by turning it clockwise (see
Fig.6). Turn the product regulator until the "0" coincides
with the arrow (see Fig.7); and perform the desired applica-
tion test, adjusting the product regulators (see Fig.8) and
range as follows:
Pressure
Aircap
2 bar
DVR HVLP
2 bar
DVR CLEAR
ENGLISH
Air consumption
Pressure
465 L/min
305 L/min
Fig.1
Fig.2
Fig.3
Fig.4
Fig.5
Fig.6
Fig.7
Fig.8
2 bar(*)
2 bar

Publicité

Table des Matières
loading

Table des Matières