09. Tips and Needles Kits
SAGOLA supplies Nozzle Kits and Tip and Needle
Kits of different sizes for a variety of different appli-
cations. In order to replace these, proceed as follows:
With the gun fully depressurised, remove the air nozzle.
Remove the Product Regulator with the spring and the spring stop and extract the needle to be
replaced. Remove the tip with the wrench supplied.
Fit the new tip and tighten. Now fit, in this order, the new needle, the spring and spring stop and
the product regulator. Lastly, fit the appropriate air nozzle.
There are Tip + needle Kits for this model of Ø 1.20, 1.20XL, 1.30, 1.30XL and 1.40.
10. Air Nozzle Kits
Air Nozzle Kits DVR TITANIA PRO, DVR AQUA, DVR HVLP and DVR CLEAR.
Air consumption
L/min
Pressure
Bar
(*) PRESSURE FOR TEST CHECKER: With the HVLP nozzle You must not exceed the maximum
inlet pressure of 1.8 bar. An excess pressure will create an additional over spray and will re-
duce the transfer.
11. Start-up
Before each start-up and especially after cleaning or repairing the unit, a check must be made
that all its elements are securely tightened.
If maintenance or repair work is to be carried out, the gun must be depressurised before work
begins (without air pressure). Should this safety measure not be observed, this may lead to
malfunctions, personal injury and accidents, which may prove to be fatal. SAGOLA S.A.U. does
not accept any responsibility for the consequences of any non-compliance with these safety re-
gulations.
Open the spray width (No.10) and pro-
duct regulators (No.20) completely (wi-
thout removing these from their housing)
by turning these anticlockwise. (See Fig.1
and Fig.2)
Place the gun on a support so that the
axis of the tank is vertical.
DVR
DVR
HVLP
TITANIA PRO
425 L/min
320 L/min
1.8 bar (
2 bar
*
)
ENGLISH
DVR
DVR
CLEAR
AQUA
305 L/min
290 L/min
2 bar
2 bar
Fig.01
Fig.02