Transport

CAUTION!
When transporting the heat pump, ensure that it is not tilted
by more than 45° (in any direction).
A pallet should be used to transport the heat pump to its final
installation location. The basic device can be transported with a
lift truck, hand truck or by means of 3/4" pipes fed through the
holes in the base plate or frame (max. pipe diameter in the evap-
orator-compressor frame area, 25 mm). In the frame area, the
pipes must run parallel to the operator side (see figure)
The heat pump and the transport pallet are joined by four tran-
sit bolts. These must be removed.
Before using the transport holes in the frame, it is necessary to
remove the two bottom side panel assemblies. Each covering
panel is secured with two screws. Once the screws have been
loosened, the covering panels can be tilted (top plates by ap-
prox. 20°, bottom plates by approx. 45°). The bottom facade
plates can then be pulled out of the skirt panel, the top facade
plates, which do not have to be removed for transport, can be
hung out of the cover plate. Rehang the top panels by gently
pushing them in an upwards direction.
NOTE
Be careful not to damage any components when inserting the
pipes through the frame.
Any transport holes are to be covered at the installation location
using the 8 black dust caps, which are included in the packag-
ing of the device.
Once the heat pump has been set up in its intended location,
the transport fastenings (2x M6 screws) must be removed from
www.glendimplex.de
the compressor plate (the front or rear panel at the bottom
must be removed for this)
transport lock
CAUTION!
Before commissioning, the transport fastening must be
removed.