If the line is free but the handshake is inva-
lid, it will end the call and go to the next tele-
phone number on the list.
G The GS3050-A will wait up to 40 seconds
for a valid handshake.
4. It will repeat the message 4 times before en-
ding the 'Successful' call.
The call will be considered 'Successful' after
the second message announcement.
If other events occur during the dialling
G
phase, the relevant messages will be sent
during the ongoing call.
This will not occur, if the 'Call successful
number' option is enabled.
The Input channel cannot generate fur-
G
ther call cycles until it has been restored to
standby.
Priority Channel - If several Alarms occur
contemporarily Alarms, channel 1 will take prio-
rity, and Channel 1 calls cycle will be sent
first. The other channels will be dealt with
chronologically.
Interface - The GSM Interface facility takes
priority over the Voice Dialler facility. Therefo-
re, if a line-sharing device (connected down-
stream to the Interface) requires the telepho-
ne line, any ongoing Voice Dialler facility calls
will be interrupted, and the calls from the line-
sharing device (e.g. Security system) will be
sent. When the line-sharing device hangs up,
the Voice Dialler facility will restart the inter-
rupted calls.
Maximum 4 tries per
Telephone number!
Phase 1
Dial Number
Figure 5 - Voice call activation phases
Dial next Telephone Number
Abort Call
End Call
NO
Phase 2
Phase 3
Dial next Telephone Number
NOTE: SMS communications take prio-
rity over Voice calls. Therefore, if the sy-
stem is programmed to send both, the
SMS communcations will be sent first.
ACTIVATING RESERVED OUTPUTS VIA SMS
The GS3050-A can be set up to control one or
more of the 5 Outputs via SMS. The communica-
tion text must include the Access code, Output
String and the required action (On/Off), as follows:
# # # # # Code# # # # # String= O N
= O N
= O N
= O N
= O N to activate the Output
# # # # # Code# # # # # String= O F F
= O F F
= O F F to stop the Output
= O F F
= O F F
The Access Code can have up to 4 alphanumeric
characters (including spaces), whereas, the String
can have up to 10. The String must be entered on
the telephone pad in the same way as it is written
in the 'Control SMS' column on the 'Outputs' page.
The following example shows an SMS communication that
will turn ON the HEATING system (Access code PR73).
# P R 7 3 # H E A T I N G = O N
# P R 7 3 # H E A T I N G = O N
# P R 7 3 # H E A T I N G = O N
# P R 7 3 # H E A T I N G = O N
# P R 7 3 # H E A T I N G = O N
NOTE: Some GSM Networks provide feedback
messages to confirm that SMS communications
have been received. If this service is not availa-
ble, you can set up one of the Input channels to
provide the feedback message. For further detai-
ls refer to the 'Output Page' section.
PROGRAMMING THE GS3050-A
G G G G G If you wish to utilize all the features of
the SMS Dialler facility, use 32 K (or
more) SIM Cards. The SIM Card must be
able to save at least 20 messages.
Phase 4
End Call
11