Instructions for Behnke SIP 2.0
GB
Hardware
hardware
8.
8.1. Compact devices Series 5/10
Connection codelock
Alarm input
–
5VDC – 18VDC
+
Ethernet connection
according to EIA/TIA 568 A
1: white-green
2: green
3: white-orange
6: orange
62
Connection speaker
Connection for extensions
LAN receptacle INPUT
(SIP intercom station to Switch)
Network connection PORT 2
(receptacle for additional IP devices,
e.g. an IP camera. Please adhere to the
technical data of the Switchport).
Master CPU
T1 + T2
Buttons to display device information (cf.
p. 58)
LEDs:
Red:
Power supply PoE
(LED illuminated: PoE available)
blue:
ready
(LED flashing Device "booting")
(max 5 min)
Green: Registered on SIP server
Tamper contact
(not activated in default status, can be
activated via the web frontend, please see
the "Help" section in the webf rontend)
Earthing
needed in case a TNV-1 circuit is used
(e.g. devices to be mounted in a column
without connection to the building)
Relay 2
max. switching voltage: 60VDC/50VAC
max. switching current: 2A
max. switching cable max 62,5VA/60W
Please note that none of the above
specifications may be exceeded
Rest contact
Control contact
Make cotact
Relay 1
max. switching voltage: 60VDC/50VAC
max. switching current: 2A
max. switching cable max 62,5VA/60W
Please note that none of the above
specifications may be exceeded
Make contact
Control contact
www.behnke-online.de