Instructions for Behnke SIP 2.0
GB
Introduction
Installation requirements
The perfect installation height for your device
is a position that enables operating the door
intercom at a distance of 30-50 cm with a
person standing in front of the device being
able to easily speak into the microphone.
Please keep the largest possible distance
between microphone and speaker. This will
give you the best possible voice quality in
full-duplex mode.
Modules for reverse-side mounting (=mount-
ing behind an existing wall) require suffi-
ciently large slits for sound to enter in front
of the microphone and for sounds to exit
from the speaker (at least 75% of the speaker
membrane surface for sound to exit or 75% for
the sound to enter the microphone housing).
Please see measurements sketches on www.
behnke-online.de/downloads
Please always mount a reverse-side mounting
module in a flush way ( without distance)
behind your front wall and do not forget to
install the included seal between front wall
and mounting module.
46
Outside mounting
When using your door intercom on a weather
side, the Series 20, 30 and 40 intercom sta-
tions should be mounted in-wall with a rain
protection cover (Please always ensure the
included seal is correctly put in place).
When mounting your Series 5, 10, 20, 30, 40
and 50 door intercom in an on-wall housing, it
is possible to route the cables to the bottom
or the rearside of the on-wall housing.
Use the included cover angle to cover the
cable route not in use. Use the PG screw
connect for cable entry.
All in-wall mounted door intercom stations
mentioned in the present manual need to be
well sealed against rain watering enter-
ing into the housing, esp. with an uneven
underground (e.g. use silicone). Please leave
the center of the bottom edge of your door
intercom station (Series 20, 30, 40 and 50)
open to serve as a water drain. When using
cover panels (for Series 5, 10, 20, 30 and 40),
the cover panel needs to be sealed with a
suitable sealing agent or with the included
seal against the in-wall housing or the level
surface for cavity wall mounting.
For mounting in steles by third-party provid-
ers, appropriate action needs to be taken to
prevent condensation water from forming
inside the stele.