hardware

4.
4.1. Compact electronics
20-0016A-IP, 20-0041A-IP, 20-0043A-IP, SPL intercom stations
(SPL intercom station is pre-assembled and can only be operated in the configurations shown in the catalogue)
Connection for
extensions
Alarm input
5VDC – 24 VDC
+

Ethernet connection

according to EIA/TIA 568 A
1: white-green
2: green
3: white-orange
6: orange
Please note: Use of extension cords 20-9305
for remote electronics up to 3m
www.behnke-online.de
20-0001A-IP, 20-0002A-IP, 20-0013A-IP, 20-0014A-IP,
Instructions for Behnke SIP 2.0
Hardware
LAN receptacle INPUT
(SIP intercom station to Switch)
Network connection PORT 2
(receptacle for additional IP devices,
e.g. an IP camera. Please adhere to the
technical data of the Switchport).
Master CPU
T1 + T2
Buttons to display device information
(cf. p. 58)
LEDs:
Red: Power supply PoE
(LED illuminated: PoE available)
blue: ready
(LED flashing Device "booting")
(max 5 min)
Green:
Registered on SIP server
Plug for module illumination
(12V) / Illumination for Behnke
wide angle IP camera
exclusively intended to branch Behnke
labels and Behnke cameras with illumi-
nation. Non-compliance can lead to a
circuit board defect.
Ribbon cable
to connect additional function modules,
e.g. buttons, speaker, microphone, etc.
Relay 2
max. switching voltage: 60VDC/50VAC
max. switching current: 2A
max. switching cable max 62,5VA/60W
Please note that none of the above specifications may
be exceeded
Operating contact
Control contact
Rest contact
Relay 1
max. switching voltage: 60VDC/50VAC
max. switching current: 2A
max. switching cable max 62,5VA/60W
Please note that none of the above specifications may
be exceeded
Operating contact
Control contact
Earthing
needed in case a TNV-1 circuit is used
(e.g. devices to be mounted in a column
without connection to the building)