Product Presentation; Security Advice; Installation Recommendations - CDVI Digicode SUBLIM Manuel D'installation

Clavier codé rétro-éclairé à électronique déportée
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
SUBLIM
Illuminated Weatherproof Keypad with remote electronics

1] PRODUCT PRESENTATION

No mechanical keys.
Backlit.
Stainless steel and polycarbonate.
Laser engraving of the numbers
and letters on the inside
of the polycarbonate material.
Free voltage.
Installation with Torx
Protection of the printed circuit
board by varnish coating.
100 user codes.
Audible and visual feedback.
Length of specifi c cable supplied (between
the SUBLIM and the remote control): 3m.
2 relays.
Dimensions (L x W x D): 205 x 175 x 63mm.
Input voltage :
- 12 to 24V ac,
- 12 to 48V dc.
Consumption (3 relays controlled + keypad):
- 12V ac > Standby 90 mA,
- 12V ac > 2 relays activated 260 mA,
- 24V ac > Standby 120 mA,
- 24V ac > 2 relays activated 150 mA,
- 12V dc > Standby 275 mA,
- 12V dc > 2 relays activated 350 mA,
- 24V dc > Standby 140 mA,
- 24V dc > 2 relays activated 175 mA.
2] NOTES AND RECOMMENDATIONS
Wiring reminder
- The wiring distance between the SUBLIM and the
remote controller must be within a maximum of 3 m.
- Take care not to pass your wires close
to «High voltage» cables (e.g.: 230 V AC).
Recommended power supplies
There are two suitable power supplies
for this Digicode
keypad: ARD12 or BS60.
®

Security advice

- The geo-positioning of the digital keys is
programmed at the factory. Once the unit has
been installed on site, repeat the geo-positioning
of the digit keys, as explained in the manual.
- For security advice reasons, change
the factory default master code.
cdvi.com
2
cdvigroup.com
screws
®
- When selecting a master code and user code
avoid simple codes (example : 3 4 5 6 7).

Installation recommendations

- To optimize the use of Sublim and prevent
unwanted interference, make sure the keypad
is mounted on a fl at, solid surface and not
subject to vibration.
- Mount the keypad on a fl at surface to avoid
any vandalism and to insure the best mounting.
- To secure the system from back electromagnetic
fi elds do not forget to mount the varistor
in parallel on the lock.
- It is essential that the SUBLIM's remote controller
is installed in an enclosed environment, protected
from external weather conditions.
10° C à +45°C
CE Certifi cation
WEEE & RoHS
Remote controller supplied
with the SUBLIM coded keypad...
WEEE & RoHS
CE C ertifi cation
-20° C to +70°C
I P52
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Digicode sérieSublim