CDVI Digicode SUBLIM Manuel D'installation page 7

Clavier codé rétro-éclairé à électronique déportée
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
SUBLIM
Illuminated Weatherproof Keypad with remote electronics
(1 2 3 4 5 default value master code).
2 beeps are emitted to confi rm
entry in programming mode.
2. Press A0 to program the key-in
keypad time and the keys lit time.
- 1 beep is emitted.
- Enter the time in 10th of second – 10
for 10 seconds up to 99 for 99 seconds
The backlighting dims 10 seconds after
the last keypress or switches off after
entering a valid code.
- Press 00 for permanent illumination keys.
- One beep is emitted to validate the time.
3. Press A1 to program relay 1
output time (door release time).
- 1 beep is emitted.
- For a latched output enter the time
in seconds – 01 for 1 second up to 99
for 99 seconds.
- Press 00 for a toggled output.
- One beep is emitted to validate the time.
4. Press B to exit from programming mode.
2 beeps are emitted to confi rm that
the keypad is in stand-by operating mode.
4 beeps indicate a data computing error.
F. RESET MASTER CODE
- On normal operating mode, set switch 1
(4 position switch SW1) to the ON position.
- Wait 1 second and then remove the jumper
by setting switch 1 to the OFF position.
- One beep is emitted.
- The master code is restored to its default
value 1 2 3 4 5 in 5-digits code and 1 2 3 4
in 4-digits code.
G. CHANGING THE ENTRY CODE BY THE USER
- Permission to change the code by the user
is determined by the position of switch 2
(4 position switch SW1).
- Set switch 2 to the OFF position to prevent
codes being changed, and to the ON position
to allow change).
1. Enter the code currently being used.
- The access relay is activated:
- A beep is emitted.
2. Enter the 2-digits sub master code.
- Relay 1, on fi rst use: A and B.
- Relay 2, on fi rst use: 1 and 3.
- A beep is emitted to authorise the change.
3. Enter the new user code.
2 beeps are emitted to confi rm the new code.
4. Check the new user code to be sure
of the modifi cation.
H. SETTING A SUB MASTER CODE
1. Enter the master code twice
(1 2 3 4 5 default value master code). 2 beeps
are emitted to confi rm entry in programming mode.
2. Relay 1 (Group 1): Type A7.
Relay 2 (Group 2): Type A8.
- This input enables you to enter new digits
for changing user codes for each group.
- A beep is emitted.
- Type the two change digits.
- A second beep is emitted to confi rm
the programming.
Eg: Type A7 then enter the two change digits.
Then repeat the operation by typing A8.
3. Press B to exit from the programming mode.
2 beeps are emitted to confi rm that the
keypad is in stand-by operating mode.
I. AUDIBLE FEEDBACK
The audible signal is enabled in programming
mode and when the relay is energised
after a valid code. To enable the audible
feedback on a key press:
1. Enter the master code twice
(1 2 3 4 5 default value master code). 2 beeps
are emitted to confi rm entry in programming mode.
2. Press AA.
- One beep is emitted.
- Press 0 to disable the audible signal
during a keypress.
- Press 1 to enable the audible signal
during a keypress.
- One beep confi rms the new setting.
3. Press B to exit from programming.
2 beeps are emitted to confi rm exit
from programming mode.