Pentair STA-RITE DS2 Serie Manuel D'installation Et D'utilisation page 5

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
LAWN SPRINKLING APPLICATION
This pump is designed for a pond, cistern or well points. Pump
discharge can be divided to supply two (2) or more sprinkler
systems. A suggested multiple dis charge to service is shown in
Figure 3.
.
Figure 3 – Multiple Discharge
PUMP/PIPING INSTALLATION
Use only PTFE pipe thread sealant tape for making all
threaded connections to the pump itself. Do not use pipe joint
compounds on plastic pumps: they can react with the plastic in
the pump components.
Make sure that all pipe joints in the suction pipe are air tight as
well as water tight. If the suction pipe can suck air, the pump
will not be able to pull water from the well.
1.
Bolt pump to solid, level foundation.
2.
Support all piping connected to the pump.
Install pump as close to well head as poss ible. Long
piping runs and many fittings create friction and
reduce flow.
3.
Wrap 1-1/2 to 2 layers of PTFE pipe thread sealant tape
clockwise (as you face end of pipe) on all male threads
being attached to pump.
Figure 4 – Bolt Pump Down
S30 (11-21-19)
4 0
6 0
2 0
8 0
1 0 0
1909 0997
3023 0997
4 0
6 0
2 0
8 0
1 0 0
Figure 5 – Independently Support All Piping Attached to Pump
4.
Tighten joints hand tight plus 1-1/2 turns. Do not
overtighten.
5.
If long, horizontal pipe runs have to be used, install a
priming tee between the check valve and the well head
(Figure 1). Use schedule 80 or iron pipe.
No Air Leaks
in Suction Pipe.
If Air Flows
Water Won't
Use PTFE Tape
Don't Hit
Thread Stops
Pump
From
Well
Body
Hand Tight Plus 1-1/2 Turns With Wrench.
3024 0997
Pipe Joint
Compound Will
Damage Plastic.
1102 0697
Don't
Overtighten
748 0993
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sta-rite ds2heSta-rite ds2hfSta-rite ds2hgSta-rite ds2hhg

Table des Matières