Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

LI 11TES
LI 16TES
Montage- und
Gebrauchsanweisung
Luft-Wasser-
Wärmepumpe
für Innenaufstellung
Bestell-Nr. | Order no. | No de commande: 452161.66.21
Installation and
Operating Instruction
Air-to-Water
Heat Pump for
Indoor Installation
Glen
Dimplex
Thermal
Solutions
Instuctions d'installation
et d'utilisation
Pompe à chaleur
air-eau pour
installation intérieure
DE | EN | FR · FD 9912
Dimplex

Publicité

loading

Sommaire des Matières pour Dimplex LI 11TES

  • Page 1 Glen Dimplex Thermal Solutions Dimplex LI 11TES LI 16TES Montage- und Installation and Instuctions d‘installation Gebrauchsanweisung Operating Instruction et d‘utilisation Luft-Wasser- Air-to-Water Pompe à chaleur Wärmepumpe Heat Pump for air-eau pour für Innenaufstellung Indoor Installation installation intérieure Bestell-Nr. | Order no. | No de commande: 452161.66.21...
  • Page 3: Table Des Matières

    LI 11TES - LI 16TES Deutsch Inhaltsverzeichnis Bitte sofort lesen ............................DE-2 1.1 Wichtige Hinweise ................................DE-2 1.2 Bestimmungsgemäßer Gebrauch ..........................DE-2 1.3 Gesetzliche Vorschriften und Richtlinien.........................DE-2 1.4 Energiesparende Handhabung der Wärmepumpe ....................DE-3 Verwendungszweck der Wärmepumpe ....................DE-3 2.1 Anwendungsbereich...............................DE-3 2.2 Arbeitsweise..................................DE-3 Lieferumfang ..............................DE-4 3.1 Grundgerät ..................................DE-4...
  • Page 4: Bitte Sofort Lesen

    Deutsch LI 11TES - LI 16TES 1.2 Bestimmungsgemäßer Bitte sofort lesen Gebrauch 1.1 Wichtige Hinweise Dieses Gerät ist nur für den vom Hersteller vorgesehenen Ver- wendungszweck freigegeben. Ein anderer oder darüber hinaus ACHTUNG! gehender Gebrauch gilt als nicht bestimmungsgemäß. Dazu Für den Betrieb und die Wartung einer Wärmepumpe sind die...
  • Page 5: Energiesparende Handhabung Der Wärmepumpe

    LI 11TES - LI 16TES Deutsch 1.4 Energiesparende Handhabung Verwendungszweck der der Wärmepumpe Wärmepumpe Mit dem Kauf dieser Wärmepumpe tragen Sie zur Schonung der Umwelt bei. Die Voraussetzung für eine energiesparende 2.1 Anwendungsbereich Betriebsweise ist die richtige Auslegung der Wärmequellen- und Wärmenutzungsanlage.
  • Page 6: Lieferumfang

    Deutsch LI 11TES - LI 16TES 3.2 Schaltkasten Lieferumfang Der Schaltkasten befindet sich in der Wärmepumpe. Nach Ab- 3.1 Grundgerät nahme der unteren Frontabdeckung und dem Lösen der sich rechts oben befindenden Befestigungsschraube kann der Die Wärmepumpe enthält unten aufgeführte Bauteile.
  • Page 7: Wärmemengenzähler Wmz

    LI 11TES - LI 16TES Deutsch 4.3 Wärmemengenzähler WMZ Transport 4.3.1 Allgemeine Beschreibung ACHTUNG! Die Wärmepumpe darf beim Transport nur bis zu einer Der Wärmemengenzähler (WMZ 25/32) dient dazu, die ange- Neigung von 45° (in jeder Richtung) gekippt werden. gebene Wärmemenge zu erfassen. Er ist als Zubehör erhältlich.
  • Page 8: Aufstellung

    Deutsch LI 11TES - LI 16TES Aufstellung Montage 6.1 Allgemein 7.1 Allgemein Die Luft/Wasser-Wärmepumpe muss in einem frostfreien und An der Wärmepumpe sind folgende Anschlüsse herzustellen: trockenen Raum auf einer ebenen, glatten und waagerechten Zu-/Abluft  Fläche aufgestellt werden. Dabei sollte der Rahmen rundum Vor-/Rückläufe der Heizungsanlage...
  • Page 9 LI 11TES - LI 16TES Deutsch Zuleitung aus Klemmkasten nach innen zurückziehen. Mutter und Federring an vier Ecken des Ventilators lösen. Ventilator leicht ins Gerät ziehen und nach vorne aus dem Gerät herausnehmen. Eventuell Verdampfer vor Beschädi- gung schützen. M 8 x 16 Distanzrohre an vier Ecken von den Befestigungsbolzen abziehen.
  • Page 10: Heizungsseitiger Anschluss

    Deutsch LI 11TES - LI 16TES 7.3 Heizungsseitiger Anschluss Mindestheizwasserdurchsatz Der Mindestheizwasserdurchsatz der Wärmepumpe ist in Die heizungsseitigen Anschlüsse an der Wärmepumpe sind mit jedem Betriebszustand der Heizungsanlage sicherzustellen. 1¼" Außengewinde versehen. Beim Anschluss an die Wärme- Dieses kann z.B. durch Installation eines doppelt differenz- pumpe muss an den Übergängen mit einem Schlüssel gegen-...
  • Page 11: Montage Der Anlegefühler

    LI 11TES - LI 16TES Deutsch 7.4.1 Fühlerkennlinien Auslegungsparameter Fühlerleitung Leitermaterial Temperatur in °C Kabellänge 50 m NTC-2 in k 14,6 11,4 Umgebungstemperatur 35 °C NTC-10 in k 67,7 53,4 42,3 33,9 27,3 22,1 18,0 B2 (DIN VDE 0298-4 /...
  • Page 12: Elektrischer Anschluss

    Deutsch LI 11TES - LI 16TES 7.5 Elektrischer Anschluss gen und ist aus diesem Grund vor dem EVU-Sperrschütz abzugreifen bzw. an den Haushaltsstrom anzuschließen, da sonst während der EVU-Sperre wichtige Schutzfunktio- 7.5.1 Allgemein nen außer Betrieb sind. Sämtliche elektrische Anschlussarbeiten dürfen nur von einer Das EVU-Sperrschütz (K22) mit 3 Hauptkontakten (1/3/5 /...
  • Page 13: Inbetriebnahme

    LI 11TES - LI 16TES Deutsch Inbetriebnahme Wärmequellen- max. Temperaturspreizung temperatur zwischen Heizungsvor- und 8.1 Allgemein Rücklauf -20 °C -15 °C Um eine ordnungsgemäße Inbetriebnahme zu gewährleisten, -14 °C -10 °C sollte diese von einem vom Werk autorisierten Kundendienst -9 °C -5 °C...
  • Page 14: Reinigung / Pflege

    Deutsch LI 11TES - LI 16TES 9.3 Reinigung Luftseite Reinigung / Pflege Luftkanäle, Verdampfer, Lüfter und Kondensatablauf sind vor 9.1 Pflege der Heizperiode von Verunreinigungen (Blätter, Zweige usw.) zu reinigen. Dazu ist die Wärmepumpe an der Frontseite zuerst Vermeiden Sie zum Schutz des Lackes das Anlehnen und Able- unten und dann oben zu öffnen.
  • Page 15: Geräteinformation

    LI 11TES - LI 16TES Deutsch 12 Geräteinformation Typ- und Verkaufsbezeichnung LI 11TES LI 16TES Bauform Wärmequelle Luft Luft Ausführung Universal Universal Regler integriert integriert Wärmemengenzählung optional (als Zubehör) optional (als Zubehör) Aufstellungsort Innen Innen Leistungsstufe Einsatzgrenzen Heizwasser-Vorlauf /-Rücklauf ° C bis 60 ±...
  • Page 16 Deutsch LI 11TES - LI 16TES Sonstige Ausführungsmerkmale Abtauart Kreislaufumkehr Kreislaufumkehr Frostschutz Kondensatwanne / Wasser im Gerät gegen Einfrieren geschützt max. Betriebsüberdruck (Wärmesenke) Heizleistung / Leistungszahlen EN 14511 EN 14511 Wärmeleistung / Leistungszahl Leistungsstufe bei A-7 / W35 kW / ---...
  • Page 17: Produktinformationen Gemäß Verordnung (Eu) Nr.813/2013, Anhang Ii, Tabelle 2

    Kontakt Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) Für Heizgeräte und Kombiheizgeräte mit Wärmepumpe ist die Wärmenennleistung Prated gleich der Auslegungslast im Heizbetrieb Pdesingh und die Wärmenennleistung eines Zusatzheizgerätes Psup gleich der zusaätzlichen Heizleistung sup(Tj ).
  • Page 18 Kontakt Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) Für Heizgeräte und Kombiheizgeräte mit Wärmepumpe ist die Wärmenennleistung Prated gleich der Auslegungslast im Heizbetrieb Pdesingh und die Wärmenennleistung eines Zusatzheizgerätes Psup gleich der zusaätzlichen Heizleistung sup(Tj ).
  • Page 19: Garantieurkunde

    LI 11TES - LI 16TES Deutsch Eine Verlängerung der Garantie auf 60 Monate oder mehr für Hei- 14 Garantieurkunde zungs-Wärmepumpen und zentrale Wohnungslüftungsgeräte ab dem Datum der Inbetriebnahme wird gemäß den nachfolgenden Glen Dimplex Thermal Solutions Bedingungen gewährt Garantieurkunde GDTS (Heizungs-Wärmepumpen, Zentrale Wohnungslüftungsgeräte)
  • Page 20 Deutsch LI 11TES - LI 16TES DE-18 452161.66.21 · FD 9912 www.gdts.one...
  • Page 21 LI 11TES - LI 16TES English sixTable of contents Please Read Immediately ..........................EN-2 1.1 Important Information:..............................EN-2 1.2 Intended Use ..................................EN-2 1.3 Legal Regulations and Directives ..........................EN-2 1.4 Energy-Efficient Use of the Heat Pump ........................EN-3 Purpose of the Heat Pump........................EN-3 2.1 Application ..................................EN-3 2.2 Operating Principle................................EN-3...
  • Page 22: Please Read Immediately

    English LI 11TES - LI 16TES 1.2 Intended Use Please Read Immediately This device is only intended for use as specified by the manu- 1.1 Important Information: facturer. Any other use beyond that intended by the manufac- turer is prohibited. This requires the user to abide by the rele- vant project planning documents.
  • Page 23: Energy-Efficient Use Of The Heat Pump

    LI 11TES - LI 16TES English 1.4 Energy-Efficient Use of the Heat Purpose of the Heat Pump Pump 2.1 Application With the purchase of this heat pump you are helping to protect the environment. A prerequisite for energy-efficient operation The air-to-water heat pump is to be used exclusively for the is the correct design of the heat source system and heating sys- heating of heating water.
  • Page 24: Scope Of Delivery

    English LI 11TES - LI 16TES 3.2 Switch Box Scope of Delivery The switch box is located in the heat pump. It can be swung out 3.1 Basic Device after removing the lower front cover and loosening the fasten- ing screw located in the upper right-hand corner.
  • Page 25: Thermal Energy Meter Wmz

    LI 11TES - LI 16TES English 4.3 Thermal energy meter WMZ Transport 4.3.1 General description ATTENTION! When transporting the heat pump, ensure that it is not tilted The thermal energy meter (WMZ 25/32) is used for measuring more than 45° (in any direction).
  • Page 26: Set-Up

    English LI 11TES - LI 16TES Set-UP Installation 6.1 General Information 7.1 General The air-to-water heat pump must be installed in a frost-free, dry The following connections need to be established on the heat room on an even, smooth and horizontal surface. The entire...
  • Page 27 LI 11TES - LI 16TES English Pull the supply cable inwards through the terminal box and nozzle panel. Loosen the nut and washers on the four corners of the fan. Pull the fan gently inside the device and pull it out through the front of the device.
  • Page 28: Heating System Connection

    English LI 11TES - LI 16TES 7.3 Heating system connection Minimum heating water flow The minimum heating water flow rate through the heat pump The heating system connections on the heat pump have a 1¼" must be assured in all operating states of the heating system.
  • Page 29: Installing The Strap-On Sensor

    LI 11TES - LI 16TES English 7.4.1 Sensor characteristic curves Dimensioning parameter sensor lead Conductor material Temperature in °C Cable-length 50 m NTC-2 in k 14.6 11.4 Ambient temperature 35 °C NTC-10 in k 67.7 53.4 42.3 33.9 27.3 22.1 18.0...
  • Page 30: Electrical Connection

    English LI 11TES - LI 16TES 7.5 Electrical connection this reason, it should be tapped upstream from the utility blocking contactor or be connected to the household current, as important protection functions may otherwise 7.5.1 General be lost during a utility block.
  • Page 31: Start-Up

    LI 11TES - LI 16TES English Start-UP Heat source max. difference between temperature heating water supply and 8.1 General Information return temperature from -20 °C -15 °C To ensure that start-up is performed correctly, it should only be -14 °C -10 °C...
  • Page 32: Maintenance / Cleaning

    English LI 11TES - LI 16TES 9.3 Cleaning the Air System Maintenance / Cleaning Air ducts, evaporator, ventilator and condensate outflow should 9.1 Maintenance be cleaned of contamination (leaves, twigs, etc.) before the heating period. Do this by opening the front of the heat pump.
  • Page 33: Device Information

    LI 11TES - LI 16TES English 12 Device Information Type and order code LI 11TES LI 16TES Design Heat source Model Universall Universall Controller Integrated Integrated Thermal energy metering Optional (as an accessory) Optional (as an accessory) Installation location Indoors...
  • Page 34 English LI 11TES - LI 16TES Additional model features Type of defrosting Reverse circulation Reverse circulation Frost protection condensate tray / water in device protected against freezing Max. operating overpressure (heat sink) Heat output / COP EN 14511 EN 14511...
  • Page 35: Product Information As Per Regulation (Eu) No 813/2013, Annex Ii, Table 2

    Contact details Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
  • Page 36 Contact details Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
  • Page 37 LI 11TES - LI 16TES Français Table des matières A lire immédiatement !..........................FR-2 1.1 Importantes informations.............................. FR-2 1.2 Utilisation conforme................................ FR-2 1.3 Dispositions légales et directives..........................FR-2 1.4 Utilisation de la pompe à chaleur pour économiser de l'énergie..............FR-3 Utilisation de la pompe à chaleur ......................FR-3 2.1 Domaine d’utilisation ..............................
  • Page 38: Lire Immédiatement

    Français LI 11TES - LI 16TES 1.2 Utilisation conforme A lire immédiatement ! Cet appareil ne doit être employé que pour l’affectation prévue 1.1 Importantes informations par le fabricant. Toute autre utilisation est considérée comme non conforme. La documentation accompagnant les projets doit également être prise en compte.
  • Page 39: Utilisation De La Pompe À Chaleur Pour Économiser De L'énergie

    LI 11TES - LI 16TES Français 1.4 Utilisation de la pompe à Utilisation de la pompe à chaleur pour économiser de chaleur l'énergie 2.1 Domaine d’utilisation En utilisant cette pompe à chaleur, vous contribuez à préserver l'environnement. La condition de base pour un mode de fonc- La pompe à...
  • Page 40: Fournitures

    Français LI 11TES - LI 16TES 3.2 Boîtier électrique Fournitures Le boîtier électrique est monté dans la pompe à chaleur. Le boî- 3.1 Appareil de base tier électrique peut être rabattu après avoir retiré l’habillage frontal inférieur et dévissé la vis de fixation se trouvant en haut La pompe à...
  • Page 41: Calorimètre Wmz

    LI 11TES - LI 16TES Français 4.3 Calorimètre WMZ Transport 4.3.1 Description générale ATTENTION ! Lors du transport, l’angle d’inclinaison de la pompe à chaleur Le calorimètre (WMZ 25/32) sert à répertorier la quantité de ne doit pas dépasser 45° (quel que soit le sens).
  • Page 42: Emplacement De Montage

    Français LI 11TES - LI 16TES Emplacement de montage Installation 6.1 Remarques d’ordre général 7.1 Généralités La pompe à chaleur air-eau doit être installée dans un local sec Les raccordements suivants doivent être réalisés sur la pompe à l'abri du gel, sur une surface plane, lisse et horizontale. Le à...
  • Page 43 LI 11TES - LI 16TES Français Tirer le câble d'alimentation vers l'intérieur, au travers du boîtier de raccordement et de la plaque de buse. Retirer les écrous et les rondelles élastiques présents aux quatre coins du ventilateur. Tirer légèrement le ventilateur vers l'intérieur de l'appareil M 8 x 16 puis le sortir par l'avant de l'appareil.
  • Page 44: Raccordement Côté Chauffage

    Français LI 11TES - LI 16TES 7.3 Raccordement côté chauffage Débit minimum d'eau de chauffage Le débit minimum d'eau de chauffage doit être garanti dans la Les raccordements côté chauffage à la pompe à chaleur sont pompe à chaleur quel que soit l'état de fonctionnement de l'ins- pourvus de filetages extérieurs 1¼".
  • Page 45: Courbes Caractéristiques De La Sonde

    LI 11TES - LI 16TES Français 7.4.1 Courbes caractéristiques de la sonde Paramètre de dimensionnement câble de sonde Matériau conducteur Température en °C Longueur de câble 50 m NTC-2 en k 14,6 11,4 Température ambiante 35 °C NTC-10 en k...
  • Page 46: Branchements Électriques

    Français LI 11TES - LI 16TES 7.5 Branchements électriques La ligne d’alimentation électrique à 3 fils du gestionnaire de pompe à chaleur (régulateur de chauffage N1) est amenée à la pompe à chaleur. 7.5.1 Généralités tension commande doit être sécurisée conformément à...
  • Page 47: Branchement Du Circulateur À Régulation Électronique

    LI 11TES - LI 16TES Français 7.5.3 Branchement du circulateur à donnant sur le côté sud et ouest. Au moins un des circuits de chauffage doit rester ouvert (par ex. salle de bains). régulation électronique La soupape différentielle est à ouvrir au maximum de telle sorte Les circulateurs à...
  • Page 48: Nettoyage / Entretien

    Français LI 11TES - LI 16TES 9.3 Nettoyage côté air Nettoyage / entretien Les conduits d’air, l’évaporateur, l’aérateur et l’écoulement des 9.1 Entretien condensats doivent être nettoyés de leurs impuretés (feuilles, branches etc.) avant la période de chauffage. Ouvrir la pompe à...
  • Page 49: Informations Sur Les Appareils

    LI 11TES - LI 16TES Français 12 Informations sur les appareils Désignation technique et commerciale LI 11TES LI 16TES Type Source de chaleur Version universelle universelle Régulateur intégré intégré Calorimètre en option (accessoire) en option (accessoire) Emplacement de montage à l'intérieur à...
  • Page 50: Autres Caractéristiques Techniques

    Français LI 11TES - LI 16TES Autres caractéristiques techniques Type de dégivrage inversion du circui inversion du circui Protection antigel cuve de condensats / eau dans l’appareil protégée du gel Surpression de service max. (dissipation thermique)) bars Puissance calorifique / COP...
  • Page 51: Informations Sur Le Produit Conformément Au Règlmenet (Ue) N° 813

    Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach Coordonnées de contact (*) Pour les dispositifs de chauffage des locaux par pompe à chaleur et les dispositifs de chauffage mixtes par pompe à chaleur, la puissance thermique nominale Prated est égale à...
  • Page 52 Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach Coordonnées de contact (*) Pour les dispositifs de chauffage des locaux par pompe à chaleur et les dispositifs de chauffage mixtes par pompe à chaleur, la puissance thermique nominale Prated est égale à...
  • Page 53: Anhang / Appendix / Annexes

    Anhang / Appendix / Annexes Maßbilder / Dimension Drawings / Schémas cotés ................A-II 1.1 Maßbild / Dimension drawing / Schéma coté LI 11TES ..................A-II 1.2 Maßbild / Dimension drawing / Schéma coté LI 16TES ..................A-III Diagramme / Diagrams / Diagrammes ....................A-IV 2.1 Kennlinien / Characterisic Curves / Courbes caractéristiques LI 11TES............
  • Page 54: Maßbilder / Dimension Drawings / Schémas Cotés

    Anhang · Appendix · Annexes LI 11TES - LI 16TES 1 Maßbilder / Dimension Drawings / Schémas cotés 1.1 Maßbild / Dimension drawing / Schéma coté LI 11TES A-II 452161.66.21 · FD 9912 www.gdts.one...
  • Page 55 LI 11TES - LI 16TES Anhang · Appendix · Annexes 1.2 Maßbild / Dimension drawing / Schéma coté LI 16TES www.gdts.one 452161.66.21 · FD 9912 A-III...
  • Page 56: Diagramme / Diagrams / Diagrammes

    Anhang · Appendix · Annexes LI 11TES - LI 16TES 2 Diagramme / Diagrams / Diagrammes 2.1 Kennlinien / Characterisic Curves / Courbes caractéristiques LI 11TES Heizleistung in [kW] Wasseraustrittstemperatur in [°C] Heating capacity in [kW] Water outlet temperature in [°C] Puissance de chauffage en [kW] Température de sortie de l'eau en [°C]...
  • Page 57 LI 11TES - LI 16TES Anhang · Appendix · Annexes 2.2 Kennlinien / Characterisic Curves / Courbes caractéristiques LI 16TES Wasseraustrittstemperatur in [°C] Heizleistung in [kW] Water outlet temperature in [°C] Heating capacity in [kW] Température de sortie de l'eau en [°C]...
  • Page 58 Anhang · Appendix · Annexes LI 11TES - LI 16TES 2.3 Einsatzgrenzendiagramm / Operating limits diagram / Diagramme des seuils d'utilisation Wasseraustritt (+/- 2 K) Water outlet (+/- 2 K) Sortie d'eau (+/- 2 K) *Wassereintritt *Water inlet *Entrée d'eau Wärmequelleneintrittstemperatur [°C]...
  • Page 59: Stromlaufpläne / Circuit Diagrams / Schémas Électriques

    LI 11TES - LI 16TES Anhang · Appendix · Annexes 3 Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1 Steuerung / Control / Commande www.gdts.one 452161.66.21 · FD 9912 A-VII...
  • Page 60 Anhang · Appendix · Annexes LI 11TES - LI 16TES 3.2 Last / Load / Charge A-VIII 452161.66.21 · FD 9912 www.gdts.one...
  • Page 61 LI 11TES - LI 16TES Anhang · Appendix · Annexes 3.3 Anschlussplan / Circuit Diagram / Schéma électrique www.gdts.one 452161.66.21 · FD 9912 A-IX...
  • Page 62 Anhang · Appendix · Annexes LI 11TES - LI 16TES 3.4 Legende / Legend / Légende Brücke EVU-Sperre: muss eingelegt werden, wenn Utility block bridge: Must be inserted if no utility Pont de blocage de la société d'électricité : à insé- kein EVU-Sperrschütz vorhanden ist( Kontakt...
  • Page 63 LI 11TES - LI 16TES Anhang · Appendix · Annexes Klemmenleiste: Einspeisung Terminal strip: Infeed Bornier distributeur : Alimentation Klemmenleiste: Spannung = 230 V AC Terminal strip: Voltage = 230 V AC Bornier distributeur : Tension = 230 V AC Klemmenleiste: Kleinspannung <...
  • Page 64: Hydraulische Einbindungsschema / Hydraulic Integration Diagrams / Schéma D'intégration Hydrauliques

    Anhang · Appendix · Annexes LI 11TES - LI 16TES 4 Hydraulische Einbindungsschema / Hydraulic integration diagrams / Schéma d’intégration hydrauliques 4.1 Monoenergetische Anlage mit einem Heizkreis / Mono energy system with one heating circuits / Installation mono-énergétique avec un circuits...
  • Page 65 LI 11TES - LI 16TES Anhang · Appendix · Annexes 4.2 Monoenergetische Anlage mit zwei Heizkreisen und Warmwasserbereitung / Mono energy system with two heating circuits and domestic hot water preparation / Installation mono- énergétique avec deux circuits de chauffage et production d'eau chaude sanitaire www.gdts.one...
  • Page 66 Anhang · Appendix · Annexes LI 11TES - LI 16TES 4.3 Bivalente Anlage mit zwei Heizkreisen und Warmwasserbereitung / Bivalent system with two heating circuits and domestic hot water preparation / Installation bivalente avec deux circuits de chauffage et production d’eau chaude sanitaire A-XIV 452161.66.21 ·...
  • Page 67 LI 11TES - LI 16TES Anhang · Appendix · Annexes 4.4 Legende / Legend / Légende Absperrventil Shut-off valve Vanne d’arrêt Sicherheitsventilkombination Safety valve combination Jeu de vannes de sécurité Umwälzpumpe Circulating pump Circulateur Ausdehnungsgefäß Expansion vessel Vase d’expansion Raumtemperaturgesteuertes Ventil Room temperature-controlled valve Vanne commandée par température...
  • Page 68: Konformitätserklärung / Declaration Of Conformity / Déclaration De Conformité

    Anhang · Appendix · Annexes LI 11TES - LI 16TES 5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité Die aktuelle CE-Konformitätserklärung finden sie als Download unter: You can find and download the current CE conformity declaration at: Vous pouvez télécharger la déclaration de conformité CE actuelle sous : https://gdts.one/li11tes...
  • Page 69 LI 11TES - LI 16TES Anhang · Appendix · Annexes www.gdts.one 452161.66.21 · FD 9912 A-XVII...
  • Page 70 Anhang · Appendix · Annexes LI 11TES - LI 16TES A-XVIII 452161.66.21 · FD 9912 www.gdts.one...
  • Page 71 LI 11TES - LI 16TES Anhang · Appendix · Annexes www.gdts.one 452161.66.21 · FD 9912 A-XIX...
  • Page 72 Glen Dimplex Deutschland GmbH Irrtümer und Änderungen vorbehalten. Geschäftsbereich GDTS Subject to alterations and errors. Am Goldenen Feld 18 Sous réserve d’erreurs et modifications. D-95326 Kulmbach +49 (0) 9221 709 924545 www.gdts.one...

Ce manuel est également adapté pour:

Li 16tes