410-00351
5
Send the transmission code to
delete the transmitter from the
selected output
4.4. Resetting an output
A separate reset can be carried out for each output.
All programmed transmitters are deleted and all switching times for the respective output are reset.
Step
Operation
1
Start the programming mode
2
Select operating mode L (delete
mode)
3
Select output.
Only one output can be selected.
Output can be changed as often as
required
4
Start the delete mode
(If you want to cancel 1x P < 1.6 s)
5
Send the transmission code to
delete all transmission codes from
the selected output and to reset
the TIMER
4.5. Resetting to factory settings
If you reset to factory settings, all settings of all outputs will be reset to the factory settings. All programmed
transmitters are deleted and all switching times are reset to the initial value.
Buttons to press
Start factory reset
Press and hold
simultaneously using 3 fingers
5.
SPECIFICATIONS
Frequency
868.30 MHz
Modulation
FSK
Protocol
Easywave
Power supply
230 V AC 50 Hz
Output
2 potential-free contacts max. 16 A / 230 V ~ (normally open)
Power consumption
0.4 W standby
max. 1.2 W without load
Connected load
see § 6
Operating temperature
-20 °C to +45 °C
Dimensions (W/L/H)
34.5 / 89.6 / 62.8 mm
Weight
108 g
6.
LOAD TABLE
Load type
max. load
Capacitive load
Dimmable LED lamps
2A / 400 VA
Ohmic load
Incandescent lamps, 230 V
16 A / 3,680 VA
halogen lamps etc.
Inductive load
Halogen lamps with wound
3 A / 690 VA
transformers (transformer at
least 85 % loaded)
Non- or serial-compensated
3 A / 690 VA
fluorescent lamps with fer-
romagnetic ballasts
Parallel-compensated
3 A / 720 VA
fluorescent lamps with fer-
romagnetic ballasts
Electronic ballast capacity
Electronic ballasts, electronic
4 A / 920 VA
transformers, etc.
EN
4
Transmitter button
LED output and 2TB and 1TB
Tx 1x briefly
light up.
When all the LEDs go out, the
receiver is ready for operation
Button to press
Display
LED 2TB flashes
1x briefly or
LED 1TB flashes
2x briefly
L
repeatedly
LED 1/2 and LED xTB flash
or
LED output and 2TB and 1TB
until (> 1.6 s)
flash quickly
LED output and 2TB and 1TB
until (> 1.6 s)
light up.
When all the LEDs go out, the
receiver is ready for operation
Display
+ press
+
shows for 4 s.
If the display is off, the
receiver is ready for operation
EN
Warnings regarding installation
The installation of products that will permanently be part of the electrical installation and which
include dangerous voltages, shall be carried out by a qualified installer and in accordance with
the applicable regulations. This user manual must be presented to the user. It should be included
in the electrical installation file and it should be passed on to any new owners. Additional copies
are available on the Niko website or via Niko customer services.
EN
CE marking
This product complies with all of the relevant European guidelines and regulations. For radio
equipment Niko llc declares that the radio equipment in this manual conforms with the 2014/53/EU
directive. If applicable, the full text of the EU Declaration of Conformity can be found on www.niko.eu.
EN
Environment
Do not dump this product with the unsorted waste. Bring it to a recognised waste collection point.
Together with producers and importers, you have an important role to play in the advancement of
sorting, recycling and reusing discarded electrical and electronic appliances. In order to finance
the waste collection and processing, the government levies a recycling contribution in some cases
(included in the purchase price of this product).
PM410-00351R21224