Types of cables and minimum thicknesses
Cable
Cable
Connection
length
type
1 < 10 m
Control panel
3G x 0.75
power supply
mm2
230 V AC
Motor power
4G x 0.75
supply 230 V AC
mm2
2 x 0.75
FROR
Flashing light
mm2
CEI
20-22
Photocell
2 x 0.5
transmitters
CEI EN
mm2
50267-
4 x 0.5
Photocell receivers
2-1
mm2
Power supply to
2 x 0.5
accessories
mm2
Control and safety
2 x 0.5
devices
mm2
Antenna
RG58
connection
If cable lengths differ from those specified in the table,
establish the cable sections depending on the actual power
draw of the connected devices and according to the provisions
of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the
dimensions on the table need to be recalculated according to
the actual power draw and distances. If connecting products
that are not contemplated in this manual, see the literature
accompanying said products.
INSTALLATION
⚠ The following illustrations are mere examples. Consider
Cable
Cable
that the space available where to fit the operator and
length
length
accessories will vary depending on the overall measurements.
10 < 20 m
20 < 30 m
It is up to each installer to select the most suitable solution.
3G x 1
3G x 1.5
Installing and assembling the container
mm2
mm2
Phases , , , ,
3G x 1
3G x 1.5
mm2
mm2
ELECTRICAL WIRING AND PROGRAMMING
2 x 1
2 x 1.5
mm2
mm2
⚠ Before starting, cut off the main power supply.
2 x 0.5
2 x 0.5
Power supply
mm2
mm2
4 x 0.5
4 x 0.5
Gearmotor
mm2
mm2
2 x 0.5
2 x 1
mm2
mm2
Warning and lighting devices
Flashing light (Contact rating: 230 V AC - 25 W max.).
2 x 0.5
2 x 0.5
It flashes while the shutter is winding up or down.
mm2
mm2
Control devices
max. 10 m
STOP button (NC contact)
Shutter cut-off button that excludes the automatic closing
cycle. To resume movement press the control button or
transmitter button. The first run will always be an opening one.
If unused, then bridge contact 1-2.
OPEN ONLY function for key switch/button for opening (NO
❷
contact)
For winding up the rolling shutter.
OPEN-STOP-CLOSE function for key switch/step-by step
button (NO contact)
For winding the shutter up or down. Pressing the button
.
and
❶
❸
or turning the key switch inverts the shutter's direction of
movement.
☞ With DIP switch 8 set to ON (maintained action activated)
contact 2-3 remains OPEN ONLY and contact 2-7 becomes
CLOSE ONLY.
Safety devices
Safety devices such as photocells, sensitive edges which are
EN 12978 Standard compliant.
Inputs C1/C7/CR on the terminal board of the panel/board
(NC contact).
When the shutter is rolling down to close, opening the
contact always inverts the movement until the shutter is fully
wound up and open.
Type of
Name
Description of function
device
When a contact is opened (when there's
an obstruction between the photocells)
2-C1
photocells
the red LED light on the cover flashes.
Bridge the input, if it is not used.
When the sensitive safety edge makes
contact (that is, when it touches an
sensitive
obstruction) the buzzer makes a sound
safety edge
2-C7
and the red LED light on the cover starts
flashing. {Bridge the input, if it is not
used.
When the sensitive safety edge makes
contact (that is, when it touches an
resistive
obstruction) the buzzer makes a sound
sensitive edge
2-CR
and the red LED light on the cover starts
flashing. Input reserved for edges with
8K2 resistor. If the input is not used,
bridge it using the issued resistor.