EN
IMPORTANT SAFETY INSTRUCTIONS FOR PEOPLE.
INCORRECT INSTALLATION MAY RESULT IN SERIOUS
HARM, FOLLOW THE INSTALLATION INSTRUCTIONS.
THIS MANUAL IS EXCLUSIVELY INTENDED FOR
PROFESSIONAL INSTALLERS OR OTHER COMPETENT
PERSONS.
LEGEND OF SYMBOLS
This symbol shows which parts to read carefully.
⚠ This symbol shows which parts describe safety issues.
☞ This symbol shows which parts to tell users about.
DESCRIPTION
The Martini control panel is a receiving unit for controlling
operators in total safety. It features a low consumption
courtesy light, step - by step button, surface LED indicator
light and a warning buzzer.
The Martini is powered by 230 V AC, with 50/60 Hz.
The command devices and accessories are powered by 24 V.
☞ The overall draw of the accessories must not exceed 50 mA.
Dimensions (mm)
Intended use
The MARTINI control panel is designed to command 230 V
single-phase motors with built in mechanical stop to be used
on rolling shutters and closures.
Any installation and/or use other than that specifi ed in this
manual is forbidden.
Limits to use
Respect cable distances and diameters as shown in the table
called "Types of cables and minimum thicknesses".
The overall power of the motor must not exceed 800 W.
Technical data
Type
Protection rating (IP)
Power supply (V - 50/60 Hz)
Power draw when idle (mA)
Power (W)
Operating temperature (°C)
Circuit insulation class
Weight (kg)
Maximum power draw of
accessories a 24 V (mA)
Container material
Fuse protecting the electronic
board (A-F)
Description of parts
1.
Connection terminal board
2.
Transformer
3.
Memorizing and Radio cancelling button
4.
Warning LED signal light
5.
Courtesy light
6.
Board cover connector
7.
Automatic closing time setting trimmer
8.
Inner door run button
9.
Function selector DIP switch
10.
Radio receiver
11.
POWER ON LED
12.
Step-by step button
13.
Warning LED
14.
Light housing
15.
Power supply cable gland, for 230 V motor output and
flashing light output
001YE0143 MARTINI
GENERAL INSTRUCTIONS FOR INSTALLING
20
Preliminary checks
230
Before installing the control panel:
85
•
make sure the area you have selected for fitting is
800
protected from any accidental collisions and that the
surface is solid enough. Use suitable screws and wall
-20/+55
plugs.
I
•
connect the control panel to the electric supply line
by means of a dual pole cut off switch with minimum
0.84
contact openings of 3 mm, and section the power
50
supply.
•
set up suitable tubes and conduits for the electric
ABS
cables to pass through, making sure they are protected
from any mechanical damage
6.3
Tools and materials
Make sure you have all the tools and materials you will need
for installing in total safety and in compliance with applicable
regulations. The figure shows some of the equipment
installers will need.
119T70558 - ver. 1 1 - 03/2014
119T70558