Adjustments
Trimmer
Function description
Adjusting the automatic closing time from a minimum
TCA TRIMMER
of 0 seconds, which excludes the function, to a
maximum of 120 seconds.
☞ During automatic closing the CLOSE LED light flashes.
The automatic close timer activates when the shutter is fully
wound up. The preset time is adjustable, and is in any case
subjected to the intervention of the safety devices and does
not activate once restoring after a total safety "stop" or if the
power is cut off.
Activating the transmitter
Additional external antenna
Disconnect the internal antenna and connect the external
one to the terminals on the board.
Memorizing transmitters
Procedure for memorizing transmitters with
sequential functions :
- With the control panel powered up, make
sure that DIP switches 6 and 7 are set to OFF.
-
Press the SET button until the PROG LED light flashes.
-
Press the button of the transmitter you want to memorize.
-
If the PROG LED light stays on, the code has been memorized.
-
Wait for the PROG LED light to turn off before performing
any other operations.
Procedure for memorizing transmitters with
separate Open-Stop-Close function :
-
With the control panel powered up, make sure that DIP
switch 6 is set to OFF and that DIP switch 7 is set to ON.
-
Press the SET button until the PROG LED light flashes.
-
Press the button of the transmitter you want to memorize.
-
If the PROG LED light stays on, the code has been memorized.
-
Wait for the PROG LED light to turn off before performing
any other operations.
A total of 25 transmitters can be memorized; if trying to
memorize one too many, the panel emits a continuous sound
for two seconds to warn that the procedure has failed.
Cancelling all of the transmitters
- With the control panel powered up, set DIP switch 6 to ON,
press the set button until the
PROG
again press the set button until the
PROG
- Once you finish reset DIP switch 6 to OFF.

FINAL OPERATIONS

Insert the board cover connector into its housing on the main
board, making sure it's in the right direction.
Tighten the cover screws.
Close the door and apply the shade.
Dismantling and disposal - Always make sure you comply
with local laws before dismantling and disposing of the
product.
Whereas other components (electronic boards, batteries,
transmitters, and so on) may contain hazardous pollutants.
These must therefore be disposed of by authorized, certifi ed
professional services.
DO NOT DISPOSE OF IN NATURE!
The data and information in this manual may be changed
at any time and without notice.
Declaration
that this device conforms with the essential requisites and
other pertinent provisions established by directive 2006/95/
CE, 2004/108/CE and 1999/05 CE.
An original copy of this declaration of conformity is
available on request.
LED light starts to flash,
LED light turns off.
- Came Cancelli Automatici S.p.A. declares
119T70558 - ver. 1 1 - 03/2014
119T70558

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

001ye0143

Table des Matières