APPLICATION

This pump is designed to be used with shallow wells down to 25 ft
(7.6 m)*, and deep wells (down to 90 ft (27.4 m)*. The pump includes
an injector kit, which consists of a cast iron injector assembly that has a
nozzle and venturi threaded into it (see Fig. 1). This injector assembly is
set-up for shallow well use. Additional venturis are included for deep well
applications. Some models also include a deep well nozzle. The venturi and
nozzle are designed specifically for certain depths to optimize performance.
The injector assembly should always be replaced at the same time the
pump is replaced. Follow the Convertible Jet Pump Injector Kit instructions
to ensure the proper venturi and nozzle are set-up in the injector assembly.
The Detailed Installation Instructions provides further information for
attaching the injector assembly. In deep well installations, friction losses in
the suction pipe must be taken into consideration (refer to Table 1, Friction
Loss Chart).
*Less at high altitudes.
This pump is not tested for use in swimming pools.
NOTE:
Nozzle
Fig. 1
Brown
115
230
Fig. 2
Venturi
Orange
Brown
Part No.
115
230
Throat
Part No.
Orange
Brown
115
230
Motor Terminal Box Cover

VOLTAGE SETTING INSTRUCTIONS

To change the pump voltage from the factory setting of 230 Volts, a
qualified electrician should:
1. Disconnect the power supply to the pump.
2. Remove the cover from the motor terminal box (see Fig. 2).
DISCONNECT UNIT FROM POWER SOURCE BEFORE PROCEEDING.
ENSURE THE PUMP'S VOLTAGE MATCHES THE VOLTAGE OF
YOUR POWER SOURCE.
Orange
Terminal Posts
Fig. 3
Fig. 3 shows the motor's switch with the black voltage change device
removed from the terminal board.
DO NOT MOVE WHITE LEAD WIRES ON L1 & L2
NOTE:
Terminal Posts
Orange
Fig. 4 (Set to 115 V)
Fig. 4 shows the motor's switch set for 115 V. The black voltage change
device is lined up so both sockets on the voltage change device are
attached to both terminal posts. The arrow lines up with the 115 V arrow
on the terminal board.
Terminal Post
Not Used
Orange
Fig. 5 (Set to 230 V)
Fig. 5 shows the motor's switch set for 230 V. The black voltage change
device is lined up so the bottom socket on the voltage change device is
attached to only one terminal post. The arrow lines up with the 230 V
arrow on the terminal board.
4
Brown
Voltage Change Device
115
230
Brown
115
230
Brown
115
230
Orange
Terminal
11
Board
Orang