I
nstallatIon guIde
General information
The installation of your HWAM stove must always comply with all national and local building regulations.
It is always a good idea to consult a chimney sweeper before you install the stove.
Always follow the instructions of the manual carefully and make sure that the installation is carried
out by a qualified professional. HWAM packaging material should always be handled in accordance
with the local rules for waste handling.
Requirements on the room
It must always be possible to obtain a supply of fresh air for the combustion to the room where the
stove is to be installed. A window that can be opened or an adjustable ventilator is considered suf-
ficient, but it is also possible to connect a HWAM fresh-air system to the stove. The air inlet/grating
must be placed so that they do not become blocked.
Fresh air system (optional extra)
The HWAM 3310 and HWAM 3320 can be equipped with an optional fresh air system.If you wish to
install a fresh air system on your stove, you have the following options:
1) Stove mounted on the wall: Connect the fresh air system on the lower back of the stove.
2) Stove mounted on a plinth: Connect the fresh air system either on the lower back of the stove or
on the back of the plinth.
Please ensure that the hole (D4) is covered by the sealing plate accompanying the fresh air con-
nection kit.
Load bearing surface
Before installing the stove, make sure that the surface it will stand on can carry the weight of the stove
and the chimney. The weight of the chimney must be calculated based on its dimensions and height.
Model
HWAM 3310 without plinth
HWAM 3310 with plinth
HWAM 3320 without plinth
HWAM 3320 with plinth
The stove is mainly made of sheet iron.
Test results
from nominal test
EN 13240
Nominal heating effect
Smoke temperature
Exhaust gas flow
Efficiency
Weight
Height
92 kg
74,1 cm
107 kg
98,0 cm
95 kg
74,2 cm
110kg
98,2 cm
HWAM 3310
5,0 kW
264ºC
7,4 g/s
80,8%
48
English
Width
Depth
58,7 cm
43,9 cm
63,1 cm
44,2 cm
59,2 cm
45,9 cm
63,6 cm
45,9 cm
HWAM 3320
5,0 kW
264ºC
7,4 g/s
80,8%