Belt Replacement; Fan And Motor Pulleys - L.B. White Foreman CI230 Manuel Du Propriétaire Et Instructions

Masquer les pouces Voir aussi pour Foreman CI230:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

18
Foreman Ductable Oil Indirect-Fired Heater
CI500 / CI750

Belt Replacement

1. Carefully remove belt from pulley.
2. Check the fan and motor pulley grooves for dirt,
clean the pulleys if needed.
3. Install new belt. Ensure belt is installed as shown
below. See directional arrow on belt.

Fan and Motor Pulleys

1. Remove belt from pulleys. See Belt Replacement.
2. Loosen allen screw on fan and motor pulleys.
3. Remove pulley and key from fan shaft and motor.
4. When installing new pulley, use a straight edge,
check motor and fan pulley alignment. Contact must
be made at edges of both pulleys.
Owner's Manual • Foreman
Fan Motor
1. Loosen electrical supply access panel screws on
motor
2. Remove access panel and gasket
3. Disconnect power supply wire.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Foreman ci500Foreman ci750

Table des Matières