5. Technical data
DC power supply:
Display:
Data retention:
Polarity of the inputs:
Input resistance:
Couting frequency:
24 V
DC power supply:
Input level:
Standard
typ. low level:
2.5 V
typ. high level:
22.0 V 10 V
Fmax:*
60 kHz 20 kHz 8 kHz
Minimum pulse length for the reset input:
Input sensitivity:
Standard sensitivity:
DC power supply: Low: 0...0.2 x U
4...30 V DC level:
Pulse shape:
Ambient temperature:
-20...+65 °C at 10...26 V DC
-20...+55 °C at >26 ...30 V DC
Storage temperature:
Altitude:
* at maximum frequency square wave pulses 1:1
10...30 V DC/max. 55 mA
with inverse-polarity
protection
6 digits, red 7 segment
LED display, height 8 mm
EEPROM
Programmable, npn or
pnp for all inputs
appr. 5 kOhm
12 V
10...30 V
5 V
2.0 V
1.0 V
4.0 V
5 ms
[V DC]
B
High: 0.6 x U
...30 V DC
B
Low: 0...2 V DC
High: 4...30 V DC
any*,
Schmitt Trigger inputs
–25...+70 °C
to 2000 m
EMC:
Noise emission
Noise immunity
Housing:
Weight:
Protection:
Cleaning:
6. Terminal assignment
1 10...30 V DC
2 0 V GND
3 INP
4 –
5 Reset
7. Ordering code
6.520.012.3X0
8. Delivery includes:
1 Digital display
1 Panel mounting clip
1 Bezel for screw mounting, panel cut out
50 x 25 mm
1 Bezel for clip mounting, panel cut out
50 x 25 mm
1 Seal
1 Multilingual operating instructions
EN 55011 Class B
EN 61000-6-2
For front panel mounting
48 x 24 mm acc. to
DIN 43700,
RAL 7021, dark grey
appr. 50 g
IP65 (front)
The front of the units is
to be cleaned only with a
soft wet (water!) cloth.
Input sensitivity
0 = Standard sensitivity
A = 4...30 V DC level
Page 3