NAOS
Quick installation and programming guide
This quick guide is a summary of the complete installation manual. The manual contains safety warnings and
other explanations which must be taken into account. The installation manual can be downloaded by going
WARNING
to the "Downloads" section of Erreka website:
http://www.erreka-automation.com
Unlocking
Unlocking for manual operation: pull the knob or
cable (1) until the release lever (2) is vertical.
Motorised operation locking: place the lever in
horizontal position (3). Locking will take place when the
operator starts up.
Elements of the complete installation
3
D260C
Assembly levels
Level H: the track should remain
10 cm above the highest point of the
door (see detail H
Total length (operator + guide) and
effective travel:
– track ref. ANA01; pos J :
3502 mm / 2741 mm
– track ref. ANA01; pos K :
3452 mm / 2691 mm
– track ref. ANA02; pos J :
4602 mm / 3841 mm
– track ref. ANA02; pos K :
4552 mm / 3791 mm
Electrical wiring
A: Main power supply
B: Closing photocells
C: Pushbutton/wall key
D: LUMI flashing light
I260B
Electrical connections
Disconnect the power supply before connecting
or disconnecting any component.
The A.T., S and STOP devices must be voltage-free in
order to prevent any damage to the control board.
A.T.
Wall key or pushbutton
S
Closing safety device (closing photocell)
AUX
Power supply for peripherals (24 Vdc)
STOP
Emergency shutdown
LAMP Warning light (24 Vdc)
Battery connection using sp+ and sp- wire
connectors (inside the frame). Charger CHG01 is
required (included in kit ADO01 with 12V 1.2Ah
batteries).
English
.
)
P260M